某导弹在自主飞振动试验中出现无物理分离信号故障,通过建立故障树并对各诱因逐一排查分析,发现是电气转接器中CAK型钽电容器失效所致。对该电容进行了失效分析并提出了改进措施,在元器件筛选环节上加严考核,可有效避免类似故障的发生。
某導彈在自主飛振動試驗中齣現無物理分離信號故障,通過建立故障樹併對各誘因逐一排查分析,髮現是電氣轉接器中CAK型鐽電容器失效所緻。對該電容進行瞭失效分析併提齣瞭改進措施,在元器件篩選環節上加嚴攷覈,可有效避免類似故障的髮生。
모도탄재자주비진동시험중출현무물리분리신호고장,통과건립고장수병대각유인축일배사분석,발현시전기전접기중CAK형단전용기실효소치。대해전용진행료실효분석병제출료개진조시,재원기건사선배절상가엄고핵,가유효피면유사고장적발생。
The physical separation signal failed to display during a missile's free flight vibration test,the cause of which is determined as the malfunction of CAK type tantalum capacitor on the electric connec- tion board via fault tree anarysis and eliminating all invalid causes.Failure analysis is conducted on the capacitor and corrective measure pointing to the failure is advanced in this paperMore severe requirement on component screening process can effectively avoid the occurrence of similar fault.