基于LabVIEW数据采集设计了电子顺磁共振信号系统.采用自制扫场电路和带有GPIB接口的高斯计,实现了扫场过程中信号电压与磁场强度的同步采集并实时显示电子顺磁共振谱线.DPPH顺磁材料的 g因子和谱线半高全宽的测试结果表明该扫场系统准确性高且重复性好.
基于LabVIEW數據採集設計瞭電子順磁共振信號繫統.採用自製掃場電路和帶有GPIB接口的高斯計,實現瞭掃場過程中信號電壓與磁場彊度的同步採集併實時顯示電子順磁共振譜線.DPPH順磁材料的 g因子和譜線半高全寬的測試結果錶明該掃場繫統準確性高且重複性好.
기우LabVIEW수거채집설계료전자순자공진신호계통.채용자제소장전로화대유GPIB접구적고사계,실현료소장과정중신호전압여자장강도적동보채집병실시현시전자순자공진보선.DPPH순자재료적 g인자화보선반고전관적측시결과표명해소장계통준학성고차중복성호.
The improvement of electronic paramagnet resonance (EPR) system was achieved by adding a self-made circuit of power amplifier ,a new data acquisition system and a high resolution gauss meter ,which were based on NI hardware and software .The measurement of EPR spectrum could be performed under conditions of simultaneously obtaining the values of EPR signal and the am-plitude of the magnetic field .The g factor and the FHMW line width of DPPH sample had been stud-ied and the result showed a high accuracy and precision .