针对近年来火力发电机组长期备用停机造成凝汽器铜管吸附膜脱落腐蚀的问题,以漳泽电力河津发电分公司系统分析研究为例,提出清洗预膜吸附膜的修补方案,并在其二号发电机组进行实施,效果良好。
針對近年來火力髮電機組長期備用停機造成凝汽器銅管吸附膜脫落腐蝕的問題,以漳澤電力河津髮電分公司繫統分析研究為例,提齣清洗預膜吸附膜的脩補方案,併在其二號髮電機組進行實施,效果良好。
침대근년래화력발전궤조장기비용정궤조성응기기동관흡부막탈락부식적문제,이장택전력하진발전분공사계통분석연구위례,제출청세예막흡부막적수보방안,병재기이호발전궤조진행실시,효과량호。
In recent years,the problem of corrosive exfoliation of asdorption membrane on condenser copper tube caused by long-term reserve shutdown at Hejin Power Generation Company was analyzed systematically. Repairing programme is proposed to clean the adsorption membrane of pre-membrane,and the programme was implemented in No.2 unit,which gained good effect.