广东化工
廣東化工
엄동화공
GUANGDONG CHEMICAL INDUSTRY
2012年
11期
142-143
,共2页
王绍楠%袁东%黄新薇%陈家强%任顺龙
王紹楠%袁東%黃新薇%陳傢彊%任順龍
왕소남%원동%황신미%진가강%임순룡
铜镍电镀废水%硫化钡
銅鎳電鍍廢水%硫化鋇
동얼전도폐수%류화패
copper-nickel electroplating wastewater%barium sulphide
文章以铜镍模拟电镀废水为研究对象,采用硫化钡法对其进行处理,以单因素实验方法考察了各个因素的影响,结果表明处理后铜离子的去除率达到了99.88%,同时镍离子的损失率仅为6.77%,因此该方法有利于资源的合理利用。
文章以銅鎳模擬電鍍廢水為研究對象,採用硫化鋇法對其進行處理,以單因素實驗方法攷察瞭各箇因素的影響,結果錶明處理後銅離子的去除率達到瞭99.88%,同時鎳離子的損失率僅為6.77%,因此該方法有利于資源的閤理利用。
문장이동얼모의전도폐수위연구대상,채용류화패법대기진행처리,이단인소실험방법고찰료각개인소적영향,결과표명처리후동리자적거제솔체도료99.88%,동시얼리자적손실솔부위6.77%,인차해방법유리우자원적합리이용。
In the paper,barium sulphide was used to treat the simulated copper-nickel electroplating wastewater,and the influences of various factors involving were investigated by single facter experiments.The results showed that when the precipitation rate of copper was 99.88 %,the loss rate of nickel was only 6.77 %.Therefore,the method could be used for the copper-nickel resources recovery and utilization from electroplating wastewater.