压缩机%回油%R410A%回油毛细管
壓縮機%迴油%R410A%迴油毛細管
압축궤%회유%R410A%회유모세관
compressor%oil return%r41OA%oil return capillary tube
对R410A家用空调系统中油分离器的回油毛细管,选择不同规格进行对比试验研究。试验结果表明,在制冷量为7200w的R410A家用空调系统中,主毛细管流量与回油毛细管流量之比为5.5%时,能较好的满足系统要求。
對R410A傢用空調繫統中油分離器的迴油毛細管,選擇不同規格進行對比試驗研究。試驗結果錶明,在製冷量為7200w的R410A傢用空調繫統中,主毛細管流量與迴油毛細管流量之比為5.5%時,能較好的滿足繫統要求。
대R410A가용공조계통중유분리기적회유모세관,선택불동규격진행대비시험연구。시험결과표명,재제랭량위7200w적R410A가용공조계통중,주모세관류량여회유모세관류량지비위5.5%시,능교호적만족계통요구。
This paper makes experimental comparison investigation on oil separator' s oil return capillary tube with different size for R410A domestic air conditioning. The result shows that it is suitable for air conditioning in capacity of 7200W using R410A as refrigerant when the ratio of the flow of main capillary tube divided by the flow of oil return capillary tube is 5.5%.