某300 MW机组对冲燃烧锅炉低氮燃烧改造中采用AireJet和DRB-4Z燃烧器,并加装了双风区OFA(燃尽风)喷口。经试验调整, OFA风箱挡板开度在50%~100%区间时对降低NOX的排放值有很好的效果。 OFA喷口二次风套筒、中心风挡板开度全开,外二次风叶片角度关小,尽量关小备用燃烧器层的风箱挡板开度,有利于降低NOX排放。在锅炉运行配风方面, OFA风箱挡板50%~100%, Aire-Jet燃烧器层风门开度35%, DRB-4Z燃烧器层风门开度在45%~55%区间,可获得降低NOX的最优效果。在300 MW工况下,省煤器出口NOX排放值由改造前的500~700 mg/m3降低至280 mg/m3以下。
某300 MW機組對遲燃燒鍋爐低氮燃燒改造中採用AireJet和DRB-4Z燃燒器,併加裝瞭雙風區OFA(燃儘風)噴口。經試驗調整, OFA風箱擋闆開度在50%~100%區間時對降低NOX的排放值有很好的效果。 OFA噴口二次風套筒、中心風擋闆開度全開,外二次風葉片角度關小,儘量關小備用燃燒器層的風箱擋闆開度,有利于降低NOX排放。在鍋爐運行配風方麵, OFA風箱擋闆50%~100%, Aire-Jet燃燒器層風門開度35%, DRB-4Z燃燒器層風門開度在45%~55%區間,可穫得降低NOX的最優效果。在300 MW工況下,省煤器齣口NOX排放值由改造前的500~700 mg/m3降低至280 mg/m3以下。
모300 MW궤조대충연소과로저담연소개조중채용AireJet화DRB-4Z연소기,병가장료쌍풍구OFA(연진풍)분구。경시험조정, OFA풍상당판개도재50%~100%구간시대강저NOX적배방치유흔호적효과。 OFA분구이차풍투통、중심풍당판개도전개,외이차풍협편각도관소,진량관소비용연소기층적풍상당판개도,유리우강저NOX배방。재과로운행배풍방면, OFA풍상당판50%~100%, Aire-Jet연소기층풍문개도35%, DRB-4Z연소기층풍문개도재45%~55%구간,가획득강저NOX적최우효과。재300 MW공황하,성매기출구NOX배방치유개조전적500~700 mg/m3강저지280 mg/m3이하。
The low NOX AireJet, DAR-4Z burners are used and OFA nozzles in dual air zone are installed in low NOX retrofit of opposed firing boilers of 300 MW units. Through test and adjustment , when OFA box damper opening is between 50% and 100%, the NOX emission can be reduced. To fully open the secondary air bushing at OFA nozzle, damper of the central air, reduce the angle of the external secondary air blade and box damper opening of standby burner can decrease NOX emission. For the air distribution for boiler op-eration, when the air box damper opens by 50% to 100%, the ventilation door of AireJet burner opens by 35%and that of DRB-4Z burner opens by 45%to 55%, the NOX emission is optimal. In case of 300 MW op-erating condition, NOX emission at economizer outlet decreases from 500~700 mg/m3 before the retrofit to 280 mg/m3 or the below.