中华临床医师杂志(电子版)
中華臨床醫師雜誌(電子版)
중화림상의사잡지(전자판)
CHINESE JOURNAL OF CLINICIANS(ELECTRONIC VERSION)
2014年
4期
678-682
,共5页
骨折愈合%生物力学%动物实验%捆绑带
骨摺愈閤%生物力學%動物實驗%捆綁帶
골절유합%생물역학%동물실험%곤방대
Fracture healing%Biomechanics%Animal experimentation%Cerclage bands
目的:探讨在骨折治疗中不同宽度的捆绑带固定对骨折愈合的生物力学影响。方法45只新西兰大白兔随机分为3组,建立胫骨干非负重骨折动物模型,应用不同宽度(3 mm,6 mm,9 mm)捆绑带固定骨折,分别于术后2、4、6周行生物力学检查进行比较。结果术后第2周6 mm的捆绑带组抗折弯、扭转、拉伸均强度居中,9 mm组优于其他两组,3 mm 组最差,有明显统计学差异(P<0.05);术后4周、6周6 mm组及3 mm组抗扭转、折弯、拉伸强度均明显增强,而9 mm组增强幅度不大。4周时6 mm组抗拉伸力与其他两组无明显统计学差异(P>0.05),抗折弯力及扭转力与9 mm组无统计学差异(P>0.05),3 mm组仍低于9 mm组,有统计学差异(P<0.05);6周时,6 mm组抗扭转力均优于其他两组,存在统计学意义(P<0.05),3 mm组优于9 mm组(P<0.05),抗折弯力及抗拉伸力6 mm组与3 mm组无统计学差异(P>0.05),均优于9 mm组(P<0.05)。结论适宜宽度的捆绑带在骨折治疗的过程中均具有较好的力学性能,并且骨折愈合的力学结果更满意。
目的:探討在骨摺治療中不同寬度的捆綁帶固定對骨摺愈閤的生物力學影響。方法45隻新西蘭大白兔隨機分為3組,建立脛骨榦非負重骨摺動物模型,應用不同寬度(3 mm,6 mm,9 mm)捆綁帶固定骨摺,分彆于術後2、4、6週行生物力學檢查進行比較。結果術後第2週6 mm的捆綁帶組抗摺彎、扭轉、拉伸均彊度居中,9 mm組優于其他兩組,3 mm 組最差,有明顯統計學差異(P<0.05);術後4週、6週6 mm組及3 mm組抗扭轉、摺彎、拉伸彊度均明顯增彊,而9 mm組增彊幅度不大。4週時6 mm組抗拉伸力與其他兩組無明顯統計學差異(P>0.05),抗摺彎力及扭轉力與9 mm組無統計學差異(P>0.05),3 mm組仍低于9 mm組,有統計學差異(P<0.05);6週時,6 mm組抗扭轉力均優于其他兩組,存在統計學意義(P<0.05),3 mm組優于9 mm組(P<0.05),抗摺彎力及抗拉伸力6 mm組與3 mm組無統計學差異(P>0.05),均優于9 mm組(P<0.05)。結論適宜寬度的捆綁帶在骨摺治療的過程中均具有較好的力學性能,併且骨摺愈閤的力學結果更滿意。
목적:탐토재골절치료중불동관도적곤방대고정대골절유합적생물역학영향。방법45지신서란대백토수궤분위3조,건립경골간비부중골절동물모형,응용불동관도(3 mm,6 mm,9 mm)곤방대고정골절,분별우술후2、4、6주행생물역학검사진행비교。결과술후제2주6 mm적곤방대조항절만、뉴전、랍신균강도거중,9 mm조우우기타량조,3 mm 조최차,유명현통계학차이(P<0.05);술후4주、6주6 mm조급3 mm조항뉴전、절만、랍신강도균명현증강,이9 mm조증강폭도불대。4주시6 mm조항랍신력여기타량조무명현통계학차이(P>0.05),항절만력급뉴전력여9 mm조무통계학차이(P>0.05),3 mm조잉저우9 mm조,유통계학차이(P<0.05);6주시,6 mm조항뉴전력균우우기타량조,존재통계학의의(P<0.05),3 mm조우우9 mm조(P<0.05),항절만력급항랍신력6 mm조여3 mm조무통계학차이(P>0.05),균우우9 mm조(P<0.05)。결론괄의관도적곤방대재골절치료적과정중균구유교호적역학성능,병차골절유합적역학결과경만의。
Objective To observe the influence of cerclage bands of three sizes on the biomechanical effects of fracture treatment. Methods Totally 45 New Zealand white rabbits were randomly divided into three groups, and the femoral shaft fracture animal models of non-weight-bearing were established. The three groups were all used with intramedullary fixation, and the cerclage bands were 3, 6, and 9 mm respectively. In 2, 4,6 weeks postoperatively, comparing biomechanics results. Results Postoperative 2 week, the 6 mm group in resistance to bending, torsion and tensile was moderate, and 9 mm group was better than the other two groups, the worst 3 mm group, there were significant statistical difference (P<0.05);Postoperative 4 weeks, 6 weeks, 6 mm and 3 mm group's data were significantly enhanced, 9 mm group increased modestly. At 4 weeks, 6mm group had no significant statistical difference (P>0.05) to the other two groups on resistance to bending force, and resistance to bending force and torque had no statistical difference (P>0.05) to 9 mm group, the 3 mm group was still less than 9 mm (P<0.05);Torsion force at 6 weeks, 6 mm group is better than the other two groups, 3 mm is better than the 9 mm group (P<0.05). Strength of resistance to bending and tensile strength of 6 mm and 3 mm group no statistical difference (P>0.05), were superior to 9 mm group (P<0.05). Conclusion 6 mm cerclage bands in the process of fracture treatment in this experiment has good mechanical properties, and the mechanics of fracture healing results more satisfied.