参照GB/T 1236-2000《工业通风机用标准化风道进行性能试验》,对同一台轴流风机的5种轴流叶轮分别进行了气动性能试验,通过对比5种轴流风机的气动性能试验数据进行分析,研究了单级轴流叶轮的叶片角度和叶片数对其性能参数的影响,得出了全压、风量、效率随叶片角度和叶片数改变的变化规律,试验结果表明:在最高效率工况条件下,首先对比相同叶片角度,不同叶片数的第一组试验系列,得出叶片数Z=6时,风量最大,功率最小。然后在相同叶片数,不同叶片角度的第二组试验系列,得出Z=6,β=38°时,风量最大,全压最大,功率最大,全压效率居中,因此得出应用于新型轴流式灭火风机的轴流叶轮最佳叶片数和叶片角度的组合。
參照GB/T 1236-2000《工業通風機用標準化風道進行性能試驗》,對同一檯軸流風機的5種軸流葉輪分彆進行瞭氣動性能試驗,通過對比5種軸流風機的氣動性能試驗數據進行分析,研究瞭單級軸流葉輪的葉片角度和葉片數對其性能參數的影響,得齣瞭全壓、風量、效率隨葉片角度和葉片數改變的變化規律,試驗結果錶明:在最高效率工況條件下,首先對比相同葉片角度,不同葉片數的第一組試驗繫列,得齣葉片數Z=6時,風量最大,功率最小。然後在相同葉片數,不同葉片角度的第二組試驗繫列,得齣Z=6,β=38°時,風量最大,全壓最大,功率最大,全壓效率居中,因此得齣應用于新型軸流式滅火風機的軸流葉輪最佳葉片數和葉片角度的組閤。
삼조GB/T 1236-2000《공업통풍궤용표준화풍도진행성능시험》,대동일태축류풍궤적5충축류협륜분별진행료기동성능시험,통과대비5충축류풍궤적기동성능시험수거진행분석,연구료단급축류협륜적협편각도화협편수대기성능삼수적영향,득출료전압、풍량、효솔수협편각도화협편수개변적변화규률,시험결과표명:재최고효솔공황조건하,수선대비상동협편각도,불동협편수적제일조시험계렬,득출협편수Z=6시,풍량최대,공솔최소。연후재상동협편수,불동협편각도적제이조시험계렬,득출Z=6,β=38°시,풍량최대,전압최대,공솔최대,전압효솔거중,인차득출응용우신형축류식멸화풍궤적축류협륜최가협편수화협편각도적조합。
According to GB/T 1236-2000 “Industrial fans---performance testing using standardized airways”,the aerody-namic performance tests of five axial-flow impellers about an axial-flow fan have been carried out respectively.By comparing and analyzing the pneumatic performance experimental data of five axial-flow fans,the influence of different blade angle and leave number of single-stage axial-flow impeller on the axial-flow fan aerodynamic performance parameters have been studied.The change situation of total pressure,dynamic pressure,power,efficiency with change of the blade angle and leave number have been obtained.The experimental results indicate that:under the most efficient operating point,firstly,compared to the same blade an-gle and different number of leaves of the first group test series,the most flow volume and smallest power of axial-flow impeller is Z=6.And compared to the same number of leaves and different blade angles of the second group test series,the most flow volume and largest total pressure of axial-flow impeller is Z=6,β=38°,it has the largest power,moderate total pressure efficiency,the best axial-flow impeller combination with blade angle and number of leaves applied in the newly axial-flow fire-fighting fan has been obtained.