当火灾烟气蔓延到楼梯间,与楼梯间相连的房间门存在门缝,烟气在门缝两侧压力梯度的驱动下流入房间。由于门缝尺寸远小于房间尺寸,热烟气流入房间后与冷空气快速混合,模拟研究了房间内的温度、一氧化碳浓度、氧气浓度等变化情况。当楼梯间被高温烟气封堵,盲目逃生很危险时,建议被困人员待在房间内采取其他方式逃生或等待救援。
噹火災煙氣蔓延到樓梯間,與樓梯間相連的房間門存在門縫,煙氣在門縫兩側壓力梯度的驅動下流入房間。由于門縫呎吋遠小于房間呎吋,熱煙氣流入房間後與冷空氣快速混閤,模擬研究瞭房間內的溫度、一氧化碳濃度、氧氣濃度等變化情況。噹樓梯間被高溫煙氣封堵,盲目逃生很危險時,建議被睏人員待在房間內採取其他方式逃生或等待救援。
당화재연기만연도루제간,여루제간상련적방간문존재문봉,연기재문봉량측압력제도적구동하류입방간。유우문봉척촌원소우방간척촌,열연기류입방간후여랭공기쾌속혼합,모의연구료방간내적온도、일양화탄농도、양기농도등변화정황。당루제간피고온연기봉도,맹목도생흔위험시,건의피곤인원대재방간내채취기타방식도생혹등대구원。
As for the only staircase,the stair hall would be filled with hot smoke very quickly,which is very unfavorable for personnel evacuation.In that case,trapped people would be burned or smoked to death if they evacuate blindly.So for that reason,a simplified model was built in this paper.The influence of door gap to the smoke flow was considered and the difference of fire parameter between the two sides of the door gap was analyzed.The result showed that the temperature,carbon monoxide concentration,oxygen concentration changed slowly in the room.This is because that the size of door gap is smaller compared with that of the room,so once the smoke flow into the room,it can mix with the surrounding air quickly and will be diluted further.That is to say,if the evacuation channels are closed by the hot smoke if a fire breaking out,waiting in the room for rescue is relatively safer than evacuation blindly.