提出了三种实现变电站中高压母线备自投和中、低压母线备自投配合的方式。其一采用延时定值保证高压母线备自投先于低压母线备自投动作;其二采用开关量保证高压母线备自投动作过程中低压母线备自投不动作;其三在备自投全部动作过程中都对备供电源电压进行检查。
提齣瞭三種實現變電站中高壓母線備自投和中、低壓母線備自投配閤的方式。其一採用延時定值保證高壓母線備自投先于低壓母線備自投動作;其二採用開關量保證高壓母線備自投動作過程中低壓母線備自投不動作;其三在備自投全部動作過程中都對備供電源電壓進行檢查。
제출료삼충실현변전참중고압모선비자투화중、저압모선비자투배합적방식。기일채용연시정치보증고압모선비자투선우저압모선비자투동작;기이채용개관량보증고압모선비자투동작과정중저압모선비자투불동작;기삼재비자투전부동작과정중도대비공전원전압진행검사。
The thesis provides three ways to cooperate automatic-switching-devices on both higher and lower voltage buses.The first is to set proper delays for the two devices so that the device on lower voltage bus operates later than the one on higher voltage bus;the second is to inform the device on lower voltage bus whether the device on higher voltage bus is in operation;the third is to check voltage of backup on every step of operation.