ICP-AES%降水%钾%钙%钠%镁
ICP-AES%降水%鉀%鈣%鈉%鎂
ICP-AES%강수%갑%개%납%미
ICP - AES%rainfall%potassium%calcium%sodium%magnesium
采用ICP-AES法对降水中的钾钙钠镁金属离子进行了测定,结果表明:各元素线性相关性均大于0.9990,加标回收率为94.4%~102.6%,相对标准偏差为0.41%~3.05%之间,均可满足要求。相比于火焰原子吸收分光光度法,该方法具有前处理简单,干扰少,测定准确、快速等特点。
採用ICP-AES法對降水中的鉀鈣鈉鎂金屬離子進行瞭測定,結果錶明:各元素線性相關性均大于0.9990,加標迴收率為94.4%~102.6%,相對標準偏差為0.41%~3.05%之間,均可滿足要求。相比于火燄原子吸收分光光度法,該方法具有前處理簡單,榦擾少,測定準確、快速等特點。
채용ICP-AES법대강수중적갑개납미금속리자진행료측정,결과표명:각원소선성상관성균대우0.9990,가표회수솔위94.4%~102.6%,상대표준편차위0.41%~3.05%지간,균가만족요구。상비우화염원자흡수분광광도법,해방법구유전처리간단,간우소,측정준학、쾌속등특점。
A method for the simultaneous determination of potassium (K), calcium(Ca), sodium (Na), and magnesium (Mg) in rainfall by ICP -AES was presented. The detection limits, accuracy and precision test were carried out. The results showed the linear correlative coefficient were higher than 0.9990, the recoveries were in the range of 94.4% 102.6% and the relative standard deviation(RSD) values were 0.41% -3.05%, and all can meet the requirements. Compared to the atomic absorption spectrometry ( AAS), the method had the advantages of simple sample preparation, less interference and fast, accurate and simultaneous multi -element analysis.