对普光气田天然气净化装置、尾气处理单元加氢进料燃烧炉及衬里结构进行了介绍。由于衬里损坏、下沉及脱落导致燃烧炉外壁超温,影响了装置正常的生产,提出了相应的改造方案。
對普光氣田天然氣淨化裝置、尾氣處理單元加氫進料燃燒爐及襯裏結構進行瞭介紹。由于襯裏損壞、下沉及脫落導緻燃燒爐外壁超溫,影響瞭裝置正常的生產,提齣瞭相應的改造方案。
대보광기전천연기정화장치、미기처리단원가경진료연소로급츤리결구진행료개소。유우츤리손배、하침급탈락도치연소로외벽초온,영향료장치정상적생산,제출료상응적개조방안。
The structure and lining form of the hydrogenation feed combustion furnace of tail gas treatment unit in natural gas purification plant were introduced .Part lining of the hydrogenation feed combustion furnace was suffered for damage ,subside ,or even fall at beginning ,which lead to over temperature of combustion furnace wall and affected normal production .Reformation plan was proposed to solve the problem existed in lining of hydrogenation feed combustion furnace .