目的:探讨优化重组技术在冠心病患者心率过快和心率波动中的诊断价值。方法选取196例确诊为冠心病的患者,据心率程度及波动范围分为四组,均行64层螺旋CT检查,以优化重组技术评估各组各支冠脉可评价率。结果四组自动重组后各支血管图像质量比较差异均有统计学意义( P<0.01),A组优于其他三组( P<0.01);再次优化重组后各支血管图像质量比较,左回旋支及右冠状动脉差异有统计学意义( P<0.01);自动重组和再次优化重组后,B、C、D组各支可评价率比较差异均有统计学意义( P<0.05或P<0.01)。结论64层螺旋CT优化重组技术可有效提高影像图像可评价率,但仍存在一定的局限和不足,检查前有效控制心率及心率波动可提高可评价率和诊断率。
目的:探討優化重組技術在冠心病患者心率過快和心率波動中的診斷價值。方法選取196例確診為冠心病的患者,據心率程度及波動範圍分為四組,均行64層螺鏇CT檢查,以優化重組技術評估各組各支冠脈可評價率。結果四組自動重組後各支血管圖像質量比較差異均有統計學意義( P<0.01),A組優于其他三組( P<0.01);再次優化重組後各支血管圖像質量比較,左迴鏇支及右冠狀動脈差異有統計學意義( P<0.01);自動重組和再次優化重組後,B、C、D組各支可評價率比較差異均有統計學意義( P<0.05或P<0.01)。結論64層螺鏇CT優化重組技術可有效提高影像圖像可評價率,但仍存在一定的跼限和不足,檢查前有效控製心率及心率波動可提高可評價率和診斷率。
목적:탐토우화중조기술재관심병환자심솔과쾌화심솔파동중적진단개치。방법선취196례학진위관심병적환자,거심솔정도급파동범위분위사조,균행64층라선CT검사,이우화중조기술평고각조각지관맥가평개솔。결과사조자동중조후각지혈관도상질량비교차이균유통계학의의( P<0.01),A조우우기타삼조( P<0.01);재차우화중조후각지혈관도상질량비교,좌회선지급우관상동맥차이유통계학의의( P<0.01);자동중조화재차우화중조후,B、C、D조각지가평개솔비교차이균유통계학의의( P<0.05혹P<0.01)。결론64층라선CT우화중조기술가유효제고영상도상가평개솔,단잉존재일정적국한화불족,검사전유효공제심솔급심솔파동가제고가평개솔화진단솔。
Objective To study the diagnostic value of restructuring optimization technology in coronary heart disease(CHD) patients with high heart rate and heart rate fluctuations .Methods According to the degree of heart rate and the range ,196 CHD patients were divided into 4 groups and examined by 64-slice CT.According to re-structuring optimization technology ,the valuable rate of each coronary artery between groups were compared .Results After automatic restructuring ,there were statistically significant difference in the evascular image quality between 4 groups(P<0.01), the image quality of group A was better than that of the other 3 groups(P<0.01); After again restructuring, the vascular image quality of left circumflex branch and right coronary artery between 4 groups were sig-nificant difference ( P <0.01 ) .After again restructuring optimization and automatic , the evaluable rates between groups B, C, D were statistically significant difference(P<0.05 or P<0.01).Conclusion 64-slice CT restructu-ring optimization technology can effectively increase the evaluable rate of video image , but there are still certain limi-tation and the insufficiency , and the effective control of heart rate and heart rate fluctuations before examination can improve the evaluable rate and the diagnostic rate .