某深沟球轴承在使用后出现保持架断裂故障。经对轴承的故障特征、理化分析和尺寸测量后发现,该轴承的钢球直径组差超差,引起接触应力增大以及附加振动载荷,导致滚道疲劳剥落和保持架断裂。
某深溝毬軸承在使用後齣現保持架斷裂故障。經對軸承的故障特徵、理化分析和呎吋測量後髮現,該軸承的鋼毬直徑組差超差,引起接觸應力增大以及附加振動載荷,導緻滾道疲勞剝落和保持架斷裂。
모심구구축승재사용후출현보지가단렬고장。경대축승적고장특정、이화분석화척촌측량후발현,해축승적강구직경조차초차,인기접촉응력증대이급부가진동재하,도치곤도피로박락화보지가단렬。
The cage fracture occurred after using a deep groove ball bearing. By analyzing the fault features of the bearing, physical and chemical analysis and measurement of the size, group deviation of the ball bearing diameter was out of tolerance, contact stress was increased and additional vibration loads, then the raceways fatigue spalling and cage fracture were resulted in.