电网技术
電網技術
전망기술
POWER SYSTEM TECHNOLOGY
2014年
9期
2532-2537
,共6页
许偲轩%陆于平%章桢%陈玉伟
許偲軒%陸于平%章楨%陳玉偉
허시헌%륙우평%장정%진옥위
充分式保护%分布式发电配电网%故障特征%故障电流幅值%继电保护
充分式保護%分佈式髮電配電網%故障特徵%故障電流幅值%繼電保護
충분식보호%분포식발전배전망%고장특정%고장전류폭치%계전보호
sufficient criterion protection%distribution network with distributed generation%fault feature%fault current amplitude%protective relaying
提出了一种新型的分布式发电配电网保护判断策略-充分式保护策略。其有别于传统保护思想要求保护方案对任何理论上可能出现的故障均有绝对的选择性,只针对那些在绝大多数情况下更有可能发生的故障,提取具有充分代表性的故障特征。传统保护方法难以解决分布式电源接入后的配电网保护问题,只能牺牲分布式电源的效率或大幅提升保护成本;充分式保护原理则是针对所提取的普遍性故障特征利用简单有效的方法优先解决。因建立在故障特性之上,保护对故障的判断是充分且可靠的。具体针对分布式发电配电网,文章分析了故障电流幅值的特征,在此基础上提出了基于电流幅值的充分式保护方案,并给出了详细的保护的判断方法和逻辑框图。在模拟分布式发电配电网的仿真中证明了充分式保护思想的实用性以及方法的正确性。
提齣瞭一種新型的分佈式髮電配電網保護判斷策略-充分式保護策略。其有彆于傳統保護思想要求保護方案對任何理論上可能齣現的故障均有絕對的選擇性,隻針對那些在絕大多數情況下更有可能髮生的故障,提取具有充分代錶性的故障特徵。傳統保護方法難以解決分佈式電源接入後的配電網保護問題,隻能犧牲分佈式電源的效率或大幅提升保護成本;充分式保護原理則是針對所提取的普遍性故障特徵利用簡單有效的方法優先解決。因建立在故障特性之上,保護對故障的判斷是充分且可靠的。具體針對分佈式髮電配電網,文章分析瞭故障電流幅值的特徵,在此基礎上提齣瞭基于電流幅值的充分式保護方案,併給齣瞭詳細的保護的判斷方法和邏輯框圖。在模擬分佈式髮電配電網的倣真中證明瞭充分式保護思想的實用性以及方法的正確性。
제출료일충신형적분포식발전배전망보호판단책략-충분식보호책략。기유별우전통보호사상요구보호방안대임하이론상가능출현적고장균유절대적선택성,지침대나사재절대다수정황하경유가능발생적고장,제취구유충분대표성적고장특정。전통보호방법난이해결분포식전원접입후적배전망보호문제,지능희생분포식전원적효솔혹대폭제승보호성본;충분식보호원리칙시침대소제취적보편성고장특정이용간단유효적방법우선해결。인건립재고장특성지상,보호대고장적판단시충분차가고적。구체침대분포식발전배전망,문장분석료고장전류폭치적특정,재차기출상제출료기우전류폭치적충분식보호방안,병급출료상세적보호적판단방법화라집광도。재모의분포식발전배전망적방진중증명료충분식보호사상적실용성이급방법적정학성。
A novel protection and judgment strategy for distribution network with distributed generation (DG), which is known as the sufficient criterion protection, is proposed. Different from traditional protection idea that demands the protection scheme to hold absolute selectivity for any type of fault that may occur theoretically, the idea of the proposed sufficient criterion protection only focuses on the fault that is more likely to happen under vast majority of cases and extracts the representative fault feature. It is hard for traditional protection methods to solve the problem of protecting the distribution network with grid-connected DG, so they have to be forced to decrease the efficiency of DG or increase the protection cost obviously, however the proposed sufficient criterion protection aims at the extracted general fault feature and adopts simple and effective means to solve the problem. Because the proposed sufficient criterion protection is based on the fault feature, the judgment of the proposed protection is sufficient and reliable. For distribution network with gird-connected DG, the feature of the amplitude of the fault current is analyzed, and on this basis a current amplitude based sufficient criterion protection scheme is put forward and the detailed judgment method for the protection and its logical block diagram are given. The practicability of the sufficient criterion protection idea and the correctness of the proposed method are validated by simulation results of distribution network with grid-connected DG.