建立波长色散X射线荧光光谱检测树脂中重金属元素的无标样分析方法。热塑性塑料在200℃热压成样片;热固性塑料取平面直接测量;涂料研磨成粉末后用硼酸镶边、衬底,经过压样机20 t压力30 s压制成样片。所有样品在真空模式下,以激发电流为50 mA,激发电压为60 kV,分光晶体为LiF(200),准直器为0.23°,测量谱线为Pb Lβ1,峰位(2θ)为28.258的仪器工作条件下测定树脂中铅的含量,通过康普顿比率判断结果的可信度。测定值与标准方法检测值相比,偏差小于10%,测定结果的相对标准偏差小于1%(n=6)。结果表明,波长色散荧光光谱无标分析方法可以快速准确地分析树脂样品中的铅含量。
建立波長色散X射線熒光光譜檢測樹脂中重金屬元素的無標樣分析方法。熱塑性塑料在200℃熱壓成樣片;熱固性塑料取平麵直接測量;塗料研磨成粉末後用硼痠鑲邊、襯底,經過壓樣機20 t壓力30 s壓製成樣片。所有樣品在真空模式下,以激髮電流為50 mA,激髮電壓為60 kV,分光晶體為LiF(200),準直器為0.23°,測量譜線為Pb Lβ1,峰位(2θ)為28.258的儀器工作條件下測定樹脂中鉛的含量,通過康普頓比率判斷結果的可信度。測定值與標準方法檢測值相比,偏差小于10%,測定結果的相對標準偏差小于1%(n=6)。結果錶明,波長色散熒光光譜無標分析方法可以快速準確地分析樹脂樣品中的鉛含量。
건립파장색산X사선형광광보검측수지중중금속원소적무표양분석방법。열소성소료재200℃열압성양편;열고성소료취평면직접측량;도료연마성분말후용붕산양변、츤저,경과압양궤20 t압력30 s압제성양편。소유양품재진공모식하,이격발전류위50 mA,격발전압위60 kV,분광정체위LiF(200),준직기위0.23°,측량보선위Pb Lβ1,봉위(2θ)위28.258적의기공작조건하측정수지중연적함량,통과강보돈비솔판단결과적가신도。측정치여표준방법검측치상비,편차소우10%,측정결과적상대표준편차소우1%(n=6)。결과표명,파장색산형광광보무표분석방법가이쾌속준학지분석수지양품중적연함량。
Determination of heavy metals in resin by wavelength dispersive X-Ray fluorescence spectrometry with standard-sample-free quantitative analysis was established. Thermoplastics was pressed into pellets at 200℃. Thermosetting plastics was detected directly. Paints were grinded into powder and pressed into pellets by 20 t power for 30 s with boric acid as a bottom. The condition of equipment was set vacuum, inspire current of 50 mA, inspire voltage of 60 kV, LiF(200) for beam splitter, collimator of 0.23°, spectral line of Pb Lβ1 and peak(2θ) at 28.258. The results determined by standard-sample-free quantitative analysis were in accordance with the results detected by standard method within deviation of 10%. The relative standard deviation of determination results was less than 1%(n=6). The Compton Ratio was used to judge the accuracy of results. The study confirmed the content of lead in resin could be determined quickly and accurately by wavelength dispersive X-Ray fluorescence spectrometry with standard-sample-free quantitative analysis.