检验医学与临床
檢驗醫學與臨床
검험의학여림상
JOURNAL OF LABORATORY MEDICINE AND CLINICAL SCIENCES
2013年
23期
3138-3139
,共2页
顾向明%胡嘉华%方玲%彭明
顧嚮明%鬍嘉華%方玲%彭明
고향명%호가화%방령%팽명
降钙素原%免疫荧光层析法%电化学发光法
降鈣素原%免疫熒光層析法%電化學髮光法
강개소원%면역형광층석법%전화학발광법
procalcitonin%immunofluorescence assay%electrochemi luminescence method
目的:采用免疫荧光层析法与电化学发光法定量检测降钙素原(PCT ),对其正确度性能进行评价。方法连续检测10 d ,每天取不同浓度的6~7份临床血清样本,其中高值18份,中值22份,低值28份,共计68份样本分别用广州万孚生物技术服务有限公司出品的免疫荧光层析法仪器与配套试剂(实验方法)和罗氏公司的电化学发光法仪器与配套试剂(比较方法)定量检测 PCT ,分析两种方法检测结果的偏倚和相关性,评估两种方法的可比性。结果两种检测方法配对 t 检验,t =0.479,单侧 t0.05(67)=1.668,故 P >0.05;直线回归检测,相关系数0.992,P<0.05,回归方程:Y =0.960 X +0.257,检测结果具较好一致性,PCT 医学决定水平0.5 ng/mL 和2.0 ng/mL 处的总符合率为97.06%。结论免疫荧光层析法与电化学发光法检测 PCT 结果具高度相关性和一致性,能够满足临床检测的基本要求。
目的:採用免疫熒光層析法與電化學髮光法定量檢測降鈣素原(PCT ),對其正確度性能進行評價。方法連續檢測10 d ,每天取不同濃度的6~7份臨床血清樣本,其中高值18份,中值22份,低值28份,共計68份樣本分彆用廣州萬孚生物技術服務有限公司齣品的免疫熒光層析法儀器與配套試劑(實驗方法)和囉氏公司的電化學髮光法儀器與配套試劑(比較方法)定量檢測 PCT ,分析兩種方法檢測結果的偏倚和相關性,評估兩種方法的可比性。結果兩種檢測方法配對 t 檢驗,t =0.479,單側 t0.05(67)=1.668,故 P >0.05;直線迴歸檢測,相關繫數0.992,P<0.05,迴歸方程:Y =0.960 X +0.257,檢測結果具較好一緻性,PCT 醫學決定水平0.5 ng/mL 和2.0 ng/mL 處的總符閤率為97.06%。結論免疫熒光層析法與電化學髮光法檢測 PCT 結果具高度相關性和一緻性,能夠滿足臨床檢測的基本要求。
목적:채용면역형광층석법여전화학발광법정량검측강개소원(PCT ),대기정학도성능진행평개。방법련속검측10 d ,매천취불동농도적6~7빈림상혈청양본,기중고치18빈,중치22빈,저치28빈,공계68빈양본분별용엄주만부생물기술복무유한공사출품적면역형광층석법의기여배투시제(실험방법)화라씨공사적전화학발광법의기여배투시제(비교방법)정량검측 PCT ,분석량충방법검측결과적편의화상관성,평고량충방법적가비성。결과량충검측방법배대 t 검험,t =0.479,단측 t0.05(67)=1.668,고 P >0.05;직선회귀검측,상관계수0.992,P<0.05,회귀방정:Y =0.960 X +0.257,검측결과구교호일치성,PCT 의학결정수평0.5 ng/mL 화2.0 ng/mL 처적총부합솔위97.06%。결론면역형광층석법여전화학발광법검측 PCT 결과구고도상관성화일치성,능구만족림상검측적기본요구。
Objective Using immunofluorescence assay and the electrochemical luminescence method for quan-titative detection of procalcitonin (PCT ) ,to evaluate the accuracy of performance .Methods 10 consecutive days ,6 to 7 clinical serum samples with different concentration of every day ,the high value of 18 ,median 22 ,low value of 28 ,a total of 68 samples were used in Guangzhou Wanfu Biological Technology Service Co immunofluorescence chromatog -raphy instruments and reagents(Experiment method) and electrochemical Roche chemiluminescence instrument and reagents(comparison method) and quantitative detection of PCT ,analysis of both bias and correlation detection re-sults ,two methods of evaluating comparability .Results Two methods for the detection of paired t test ,t = 0 .479 , t0 .05(67) = 1 .668 ,P > 0 .05 ;Linear regression analysis ,r = 0 .992 ,> 0 .975 .The regression equation :Y = 0 .960 X +0 .257 ,the detection results have good consistency ,PCT medical decision the total coincidence rate of 97 .06% levels of 0 .5ng/ml and 2 .0ng/ml .Conclusion Compared with experimental method in the detection of PCT with a high de-gree of correlation and consistency ,to meet the basic requirements of clinical detection .