该文选取光纤消逝波传感器为研究对象,测量了纯净水、球形玻璃碳悬浊液和石墨悬浊液的常规透过谱和光纤消逝波谱。研究发现对于片状石墨悬浊液和球形玻璃碳悬浊液透过谱,透过信号的强度和形状存在差别,我们从悬浮颗粒的形状、大小以及消逝波的穿透深度等方面给出了合理解释。
該文選取光纖消逝波傳感器為研究對象,測量瞭純淨水、毬形玻璃碳懸濁液和石墨懸濁液的常規透過譜和光纖消逝波譜。研究髮現對于片狀石墨懸濁液和毬形玻璃碳懸濁液透過譜,透過信號的彊度和形狀存在差彆,我們從懸浮顆粒的形狀、大小以及消逝波的穿透深度等方麵給齣瞭閤理解釋。
해문선취광섬소서파전감기위연구대상,측량료순정수、구형파리탄현탁액화석묵현탁액적상규투과보화광섬소서파보。연구발현대우편상석묵현탁액화구형파리탄현탁액투과보,투과신호적강도화형상존재차별,아문종현부과립적형상、대소이급소서파적천투심도등방면급출료합리해석。
This paper is focused on the application of fiber evanescent sensors in extraction spectral information in turbid liquid. The bulk transmitted spectra of graphite flakes and glassy carbon suspension with various concentrations were recorded. The reasons for different influences of graphite flakes and glassy carbon particles turbid liquid on transmitted spectra were analyzed on the basis of particles morphology, size and transmitted depth of evanescent field wave.