推导了电力系统稳定器(PSS)参数灵敏度指标的计算过程,并在小干扰稳定分析软件SSAP中实现了2种灵敏度计算功能,即振荡模式特征值及其阻尼比对PSS参数灵敏度的计算功能,以及控制器等效交流增益不变约束下的振荡模式特征值及其阻尼比对控制器补偿相位的灵敏度的计算功能,可以对低频振荡阻尼进行优化(或约束优化)。以红海湾电厂600 MW机组为例,通过PSS参数的灵敏度分析对低频振荡阻尼进行约束优化,特征值分析与现场抗扰动试验的实测录波结果相吻合,验证了SSAP灵敏度分析理论与计算的准确性及其在工程中的指导作用。
推導瞭電力繫統穩定器(PSS)參數靈敏度指標的計算過程,併在小榦擾穩定分析軟件SSAP中實現瞭2種靈敏度計算功能,即振盪模式特徵值及其阻尼比對PSS參數靈敏度的計算功能,以及控製器等效交流增益不變約束下的振盪模式特徵值及其阻尼比對控製器補償相位的靈敏度的計算功能,可以對低頻振盪阻尼進行優化(或約束優化)。以紅海灣電廠600 MW機組為例,通過PSS參數的靈敏度分析對低頻振盪阻尼進行約束優化,特徵值分析與現場抗擾動試驗的實測錄波結果相吻閤,驗證瞭SSAP靈敏度分析理論與計算的準確性及其在工程中的指導作用。
추도료전력계통은정기(PSS)삼수령민도지표적계산과정,병재소간우은정분석연건SSAP중실현료2충령민도계산공능,즉진탕모식특정치급기조니비대PSS삼수령민도적계산공능,이급공제기등효교류증익불변약속하적진탕모식특정치급기조니비대공제기보상상위적령민도적계산공능,가이대저빈진탕조니진행우화(혹약속우화)。이홍해만전엄600 MW궤조위례,통과PSS삼수적령민도분석대저빈진탕조니진행약속우화,특정치분석여현장항우동시험적실측록파결과상문합,험증료SSAP령민도분석이론여계산적준학성급기재공정중적지도작용。
Parameter sensitivity indices of power system stabilizer(PSS) are introduced and sensitivity computation function are implemented in SSAP power system software package by two approaches;(i) the sensitivity computation function of eigenvalues associated with oscillation modes and their damping ratios via PSS controller parameters;and(ii) the sensitivity computation function of the eigenvalues of oscillation modes and their damping ratios via PSS parameters subject to the condition of constant equivalent AC gain.Low frequency oscillation damping is optimized in both approaches.The 600 MW generator in Honghaiwan power station is taken for case study.The parameter of PSS is optimized by sensitivity analysis subject to constant equivalent AC gain.The optimized results well coincide with the oscillograms recorded during the on site experiment.The sensitivity analysis by SSAP is validated not only by theoretic analysis but also by engineering practice.