目的:比较全髋关节置换术采用ABG柄和SECUR-FIT HA柄对假体周围骨密度的改变,并分析影响因素。方法对我院2010年1月至2013年1月的56例(68侧)的全髋关节置换患者,27例(34侧)患者采用ABG柄(史塞克,美国),29例(34侧)采用SECUR-FIT HA柄(史塞克,美国)进行手术。术后我们采用双能量X线吸收测量法对两种股骨假体柄周围的骨密度进行测量,并进行比较。假体骨质分区方法采用Gruen法。结果 ABG组和SECUR-FIT HA组在1区和7区骨密度改变均有显著性差异( P<0.05);SECUR-FIT HA组在2、6区骨密度改变同术前相比较有显著性差异( P<0.05)。结论解剖柄能够减少应力遮挡作用,因此,ABG柄比SECUR-FIT HA柄骨量丢失范围小。
目的:比較全髖關節置換術採用ABG柄和SECUR-FIT HA柄對假體週圍骨密度的改變,併分析影響因素。方法對我院2010年1月至2013年1月的56例(68側)的全髖關節置換患者,27例(34側)患者採用ABG柄(史塞剋,美國),29例(34側)採用SECUR-FIT HA柄(史塞剋,美國)進行手術。術後我們採用雙能量X線吸收測量法對兩種股骨假體柄週圍的骨密度進行測量,併進行比較。假體骨質分區方法採用Gruen法。結果 ABG組和SECUR-FIT HA組在1區和7區骨密度改變均有顯著性差異( P<0.05);SECUR-FIT HA組在2、6區骨密度改變同術前相比較有顯著性差異( P<0.05)。結論解剖柄能夠減少應力遮擋作用,因此,ABG柄比SECUR-FIT HA柄骨量丟失範圍小。
목적:비교전관관절치환술채용ABG병화SECUR-FIT HA병대가체주위골밀도적개변,병분석영향인소。방법대아원2010년1월지2013년1월적56례(68측)적전관관절치환환자,27례(34측)환자채용ABG병(사새극,미국),29례(34측)채용SECUR-FIT HA병(사새극,미국)진행수술。술후아문채용쌍능량X선흡수측량법대량충고골가체병주위적골밀도진행측량,병진행비교。가체골질분구방법채용Gruen법。결과 ABG조화SECUR-FIT HA조재1구화7구골밀도개변균유현저성차이( P<0.05);SECUR-FIT HA조재2、6구골밀도개변동술전상비교유현저성차이( P<0.05)。결론해부병능구감소응력차당작용,인차,ABG병비SECUR-FIT HA병골량주실범위소。
Objective To compare the change of periprosthetic bone mineral density ( BMD) after the total hip replacement with ABG and SECUR-FIT HA femoral component, and to analyze the influential factors.Methods A total of 56 patients (68 hips), who underwent the total hip replacement in our hospital from January 2010 to January 2013, were selected.Among these patients, 27 patients (34 hips) underwent the total hip replacement with the ABG stem ( Stryker, American), and 29 patients (34 hips) with SECUR-FIT HA stem (Stryker, American).The periprosthetic bone mineral density (BMD) of the femur was detected using dual-energy X-ray absorptiometry and compared between the two groups .The bone resorption area was calculated and recorded according to the Gruen’s standard.Results The change of BMD in zone 1 and 7 in two groups were significant different (P<0.05).In the SECUR-FIT HA stem group, the change of BMD in zone 2 and 6 was significant different to that before the operation (P<0.05). Conclusion The ABG stem can reduce the stress shielding .Thus, the bone resorption area around the ABG stem is smaller than that around the SECUR-FIT HA stem.