2012年
7期
10-13
,共4页
邹燕%郑春苏%罗慧屏%黄文硕%容海鹰%黄清松
鄒燕%鄭春囌%囉慧屏%黃文碩%容海鷹%黃清鬆
추연%정춘소%라혜병%황문석%용해응%황청송
免疫透射比浊法%视黄醇结合蛋白,参考值建立
免疫透射比濁法%視黃醇結閤蛋白,參攷值建立
면역투사비탁법%시황순결합단백,삼고치건립
Immune turbidimetric method%Retinol binding protein%Establishment of reference value
目的:建立本实验室应用免疫透射比浊法测定成人血清视黄醇结合蛋白(RBP)的参考值范围。方法:使用全自动生化分析仪和免疫透射比浊法试剂盒检测广州地N500名健康成年男性和女性新鲜空腹静脉血清中RBP,按照年龄和性别分别统计其结果,将均数±1.96标准差确定为参考值范围。结果:检测结果在任意两个年龄段之间差异均无统计学意义(t=1.972,P〉0.05),但男、女性别之间差异有统计学意义(t=1.965,P〈0.05):男性为49.3±11.8mg/L,女性为46.2±12.3mg/L。结论:本实验室应用免疫透射比浊法测定成人血清RBP的参考值范围确定为:男性49.3±23.1mg/L,女性46.2±24.1mg/L;在建立参考值范围时应考虑和分析仪器、检测方法、地域、年龄、性别等影响因素。
目的:建立本實驗室應用免疫透射比濁法測定成人血清視黃醇結閤蛋白(RBP)的參攷值範圍。方法:使用全自動生化分析儀和免疫透射比濁法試劑盒檢測廣州地N500名健康成年男性和女性新鮮空腹靜脈血清中RBP,按照年齡和性彆分彆統計其結果,將均數±1.96標準差確定為參攷值範圍。結果:檢測結果在任意兩箇年齡段之間差異均無統計學意義(t=1.972,P〉0.05),但男、女性彆之間差異有統計學意義(t=1.965,P〈0.05):男性為49.3±11.8mg/L,女性為46.2±12.3mg/L。結論:本實驗室應用免疫透射比濁法測定成人血清RBP的參攷值範圍確定為:男性49.3±23.1mg/L,女性46.2±24.1mg/L;在建立參攷值範圍時應攷慮和分析儀器、檢測方法、地域、年齡、性彆等影響因素。
목적:건립본실험실응용면역투사비탁법측정성인혈청시황순결합단백(RBP)적삼고치범위。방법:사용전자동생화분석의화면역투사비탁법시제합검측엄주지N500명건강성년남성화녀성신선공복정맥혈청중RBP,안조년령화성별분별통계기결과,장균수±1.96표준차학정위삼고치범위。결과:검측결과재임의량개년령단지간차이균무통계학의의(t=1.972,P〉0.05),단남、녀성별지간차이유통계학의의(t=1.965,P〈0.05):남성위49.3±11.8mg/L,녀성위46.2±12.3mg/L。결론:본실험실응용면역투사비탁법측정성인혈청RBP적삼고치범위학정위:남성49.3±23.1mg/L,녀성46.2±24.1mg/L;재건립삼고치범위시응고필화분석의기、검측방법、지역、년령、성별등영향인소。
Objective: To establish our laboratory reference range of adult's retinol-binding protein(RBP) determined used immune turbidimetric method in serum. Methods: Using automatic biochemical analyzer and kit of immune turbidimetric method for detection of RBP in fresh fasting venous serum of 500cases healthy adults' men and women in Guangzhou district, According to age and gender statistics results, mean_+l.96 standard deviation is determined for the reference value range. Results: The test results in no significant differencebetween any two ages(t = 1.972, P〉0.05), but significant differences between the sexes(t = 1.965, P〈0.05): male was 49.3± 11.8 mg/L, the female was 46.2±12.3 mg / L. Conclusion: Our laboratory's reference value ranges of adult's RBP determined used immune turbidimetric method in serum is Identified as follows: males 49.3±23. lmg/L, female 46.2±24.1mg / L; the instrument, analytical method, region, age ,gender and other influence factors should be considered and analyzed When establishing the reference ranges.