热电制冷%新风换气机%COP%余热回收
熱電製冷%新風換氣機%COP%餘熱迴收
열전제랭%신풍환기궤%COP%여열회수
thermoelectric refrigeration%fresh air ventilator%COP%waste heat recovery
在热电热泵热力学分析的基础上,本文研制了一种新型住宅用热电热管式新风换气机,并对热电新风换气机的性能进行初步实验研究,结果表明:该新风换气机的最佳工作电压为5V,在该电压工作时新风换气机制冷系数在2.3以上,制热系数在3.1以上。
在熱電熱泵熱力學分析的基礎上,本文研製瞭一種新型住宅用熱電熱管式新風換氣機,併對熱電新風換氣機的性能進行初步實驗研究,結果錶明:該新風換氣機的最佳工作電壓為5V,在該電壓工作時新風換氣機製冷繫數在2.3以上,製熱繫數在3.1以上。
재열전열빙열역학분석적기출상,본문연제료일충신형주택용열전열관식신풍환기궤,병대열전신풍환기궤적성능진행초보실험연구,결과표명:해신풍환기궤적최가공작전압위5V,재해전압공작시신풍환기궤제랭계수재2.3이상,제열계수재3.1이상。
Based on the thermodynamic analysis on a thermoelectric heat pump system, fresh air ventilator integrated thermoelectric and heat pipe was developed for residence, and primary tests were carried out. The experiment results show that the best work voltage is 5V, and the COP of this ventilator was found to be over 2.3 in cooling and 3.1 in heating mode under the operating condition.