无线电波透视%震波透视CT%三维电法%陷落柱
無線電波透視%震波透視CT%三維電法%陷落柱
무선전파투시%진파투시CT%삼유전법%함락주
radio-wave penetration%seismic wave CT%3D electric method%subsidence column
煤层工作面内陷落柱与煤层之间具有显著的电阻率、波速和密度差异,适宜于采用无线电波透视法和震波透视CT法来探测煤层工作面内陷落柱的边界范围;陷落柱体通常裂隙发育,与围岩相比较,其富水陷落柱为相对低电阻率值范围,而不富水陷落柱则为相对高电阻率值范围,因此,可利用煤层底板三维电法来探查底板陷落柱富水性。谢桥矿13218工作面1#陷落柱的探测表明,该陷落柱范围具有较高的电磁波吸收系数特征和相对较高的纵波波速特征;工作面底板陷落柱向下范围为相对高电阻率值特征,为不富水陷落柱。该综合物探探测结果与实际验证资料基本吻合,有效地指导了本煤层工作面开采及底板煤层工作面的开采设计与施工。
煤層工作麵內陷落柱與煤層之間具有顯著的電阻率、波速和密度差異,適宜于採用無線電波透視法和震波透視CT法來探測煤層工作麵內陷落柱的邊界範圍;陷落柱體通常裂隙髮育,與圍巖相比較,其富水陷落柱為相對低電阻率值範圍,而不富水陷落柱則為相對高電阻率值範圍,因此,可利用煤層底闆三維電法來探查底闆陷落柱富水性。謝橋礦13218工作麵1#陷落柱的探測錶明,該陷落柱範圍具有較高的電磁波吸收繫數特徵和相對較高的縱波波速特徵;工作麵底闆陷落柱嚮下範圍為相對高電阻率值特徵,為不富水陷落柱。該綜閤物探探測結果與實際驗證資料基本吻閤,有效地指導瞭本煤層工作麵開採及底闆煤層工作麵的開採設計與施工。
매층공작면내함락주여매층지간구유현저적전조솔、파속화밀도차이,괄의우채용무선전파투시법화진파투시CT법래탐측매층공작면내함락주적변계범위;함락주체통상렬극발육,여위암상비교,기부수함락주위상대저전조솔치범위,이불부수함락주칙위상대고전조솔치범위,인차,가이용매층저판삼유전법래탐사저판함락주부수성。사교광13218공작면1#함락주적탐측표명,해함락주범위구유교고적전자파흡수계수특정화상대교고적종파파속특정;공작면저판함락주향하범위위상대고전조솔치특정,위불부수함락주。해종합물탐탐측결과여실제험증자료기본문합,유효지지도료본매층공작면개채급저판매층공작면적개채설계여시공。
Between coalface subsidence column and coal seams have provided with distinct resistivity, wave velocity and density differ-ences, thus suitable for radio-wave penetration method and seismic wave CT method to detect subsidence column limits within coalface. Commonly, fissures are well developed in subsidence columns;compared with surrounding rocks, water rich columns have relatively low resistivity, while columns without water relatively high. Thus, the 3D electric method can be used to detect coal floor floor subsidence column water yield property. The detection of No.1 subsidence column in the Xieqiao coalmine No.13218 coalface has shown that within the column limits has higher electromagnetic wave absorption coefficient and relatively high compression wave velocity. Coalface floor subsidence column downward has relatively high resistivity, thus a column without rich water. The results of integrated geophysical pros-pecting are basically accord with practical validated data, effectively guided the coalface winning and coalface design and operation.