电力系统自动化
電力繫統自動化
전력계통자동화
AUTOMATION OF ELECTRIC POWER SYSTEMS
2013年
22期
96-100
,共5页
金丹%徐春营%岳鑫桂%齐金伟%田晶晶
金丹%徐春營%嶽鑫桂%齊金偉%田晶晶
금단%서춘영%악흠계%제금위%전정정
Rogowski线圈%低频失真%校正电路%雷电流
Rogowski線圈%低頻失真%校正電路%雷電流
Rogowski선권%저빈실진%교정전로%뇌전류
Rogowski coil%low-frequency distortion%correcting circuit%lightning current
自积分式Rogowski线圈用于输电线路雷电流测量时,由于雷电流含有丰富的低频成分,往往导致测量得到的雷电流波形出现低频失真现象,影响雷电流参数的精确测量。为此,经过对自积分式Rogowski线圈低频失真现象产生机理的理论分析及雷电流频谱分析,提出了一种基于新型模拟积分补偿电路的低频失真校正方法,用以对被测电流逆向还原,分析了电路的工作原理并根据Rogowski线圈的电磁参数计算出电路各元件的参数值,此外,电路中的二阶高通滤波电路可以滤除工频负荷电流对Rogowski线圈的电磁干扰。实验结果表明:该方法简单可行,提高了自积分式Rogowski线圈的低频响应性能,解决了 Rogowski 线圈雷电流测量中的低频失真问题;在已投入的输电线路雷击故障定位系统实际应用中,有效提高了故障行波电流测量的精度和可靠性。
自積分式Rogowski線圈用于輸電線路雷電流測量時,由于雷電流含有豐富的低頻成分,往往導緻測量得到的雷電流波形齣現低頻失真現象,影響雷電流參數的精確測量。為此,經過對自積分式Rogowski線圈低頻失真現象產生機理的理論分析及雷電流頻譜分析,提齣瞭一種基于新型模擬積分補償電路的低頻失真校正方法,用以對被測電流逆嚮還原,分析瞭電路的工作原理併根據Rogowski線圈的電磁參數計算齣電路各元件的參數值,此外,電路中的二階高通濾波電路可以濾除工頻負荷電流對Rogowski線圈的電磁榦擾。實驗結果錶明:該方法簡單可行,提高瞭自積分式Rogowski線圈的低頻響應性能,解決瞭 Rogowski 線圈雷電流測量中的低頻失真問題;在已投入的輸電線路雷擊故障定位繫統實際應用中,有效提高瞭故障行波電流測量的精度和可靠性。
자적분식Rogowski선권용우수전선로뇌전류측량시,유우뇌전류함유봉부적저빈성분,왕왕도치측량득도적뇌전류파형출현저빈실진현상,영향뇌전류삼수적정학측량。위차,경과대자적분식Rogowski선권저빈실진현상산생궤리적이론분석급뇌전류빈보분석,제출료일충기우신형모의적분보상전로적저빈실진교정방법,용이대피측전류역향환원,분석료전로적공작원리병근거Rogowski선권적전자삼수계산출전로각원건적삼수치,차외,전로중적이계고통려파전로가이려제공빈부하전류대Rogowski선권적전자간우。실험결과표명:해방법간단가행,제고료자적분식Rogowski선권적저빈향응성능,해결료 Rogowski 선권뇌전류측량중적저빈실진문제;재이투입적수전선로뢰격고장정위계통실제응용중,유효제고료고장행파전류측량적정도화가고성。
When self-integrator Rogowski coil is used for measuring lightning current on transmission lines,because of the rich low-frequency component contained,the lightning current waveform measured often tends to be in low-frequency distortion, affecting the accurate measurement of lightning current parameters.Therefore,according to a theoretical analysis of the low-frequency distortion mechanism of self-integrator Rogowski coil and an analysis of lightning current spectrum,a low-frequency distortion correction method based on a new integral compensation circuit is put forward for restoring the original measured current retroactively.The working principle of the circuit is also dealt with,and the circuit parameter value of each element is calculated based on electromagnetic parameters of Rogowski coil.Furthermore,the second-order high-pass filter circuit can be used to filter out the electromagnetic interference in Rogowski coil caused by the power frequency current.Experimental results show that the method is simple and feasible,the low-frequency response performance of self-integrator Rogowski coil is improved,the problem of low-frequency distortion of Rogowski coil used for measuring lightning current is solved.Adoption of the method for a transmission line lightning fault location system has effectively improved the measurement precision and reliability of the fault traveling wave current.