隐匿性肋骨骨折%影像学诊断%多层螺旋CT%多维重建
隱匿性肋骨骨摺%影像學診斷%多層螺鏇CT%多維重建
은닉성륵골골절%영상학진단%다층라선CT%다유중건
Occult rib fractures%diagnostic imaging%multislice spiral CT%dimensional reconstruction
目的:考察多层螺旋CT(MSCT)联合多维重建技术对隐匿性肋骨骨折的临床诊断价值,为该类疾病临床诊断提供参考。方法:以我院2012年7月至2014年2月间收治的73例隐匿性肋骨骨折患者为研究对象,使用MSCT联合VR、SSD、CRP等多种重建技术对患者进行检查,统计并分析影像学检查结果。结果:73例患者经MSCT检查确诊隐匿性肋骨骨折107处,骨折多发于肋骨角(59.81%)且以非完全线性骨折为主(91.59%)。所用多维重建技术的诊断精度依次为:CRP(100.0%)>MPR(97.19%)>SSD(85.89%)>VR(78.50%)>MIP(27.88%)。结论:MSCT联合多维重建技术对隐匿性肋骨骨折具有较为明确的诊断价值,MSCT与CRP/MPR及VR等联用可获得较为理想的诊断率。
目的:攷察多層螺鏇CT(MSCT)聯閤多維重建技術對隱匿性肋骨骨摺的臨床診斷價值,為該類疾病臨床診斷提供參攷。方法:以我院2012年7月至2014年2月間收治的73例隱匿性肋骨骨摺患者為研究對象,使用MSCT聯閤VR、SSD、CRP等多種重建技術對患者進行檢查,統計併分析影像學檢查結果。結果:73例患者經MSCT檢查確診隱匿性肋骨骨摺107處,骨摺多髮于肋骨角(59.81%)且以非完全線性骨摺為主(91.59%)。所用多維重建技術的診斷精度依次為:CRP(100.0%)>MPR(97.19%)>SSD(85.89%)>VR(78.50%)>MIP(27.88%)。結論:MSCT聯閤多維重建技術對隱匿性肋骨骨摺具有較為明確的診斷價值,MSCT與CRP/MPR及VR等聯用可穫得較為理想的診斷率。
목적:고찰다층라선CT(MSCT)연합다유중건기술대은닉성륵골골절적림상진단개치,위해류질병림상진단제공삼고。방법:이아원2012년7월지2014년2월간수치적73례은닉성륵골골절환자위연구대상,사용MSCT연합VR、SSD、CRP등다충중건기술대환자진행검사,통계병분석영상학검사결과。결과:73례환자경MSCT검사학진은닉성륵골골절107처,골절다발우륵골각(59.81%)차이비완전선성골절위주(91.59%)。소용다유중건기술적진단정도의차위:CRP(100.0%)>MPR(97.19%)>SSD(85.89%)>VR(78.50%)>MIP(27.88%)。결론:MSCT연합다유중건기술대은닉성륵골골절구유교위명학적진단개치,MSCT여CRP/MPR급VR등련용가획득교위이상적진단솔。
Objective:To investigate the clinical value of the multi-slice CT and for multi-dimensional reconstruction techniques the diagnosis of occult rib fracture, to provide a reference for the diagnosis of occult rib fracture.Methods:73 cases patients with occult rib fracture which received treatment during 2012.07 to 2014. 02, were the objects for this study, used MSCT joint VR, SSD, CRP and other reconstruction techniques to detected the occult rib fracture of all the patients, and then the imaging results of the patients were analyzed. Results:The results of MSCT showed 107 occult rib fracture were detected for 73 cases patients, and about 59.81% occult rib fracture were occurred in the rib angle, and the non- fully linear fracture dominated 91.59%. The diagnostic accuracy of all the multi-dimensional reconstruction techniques used in this study were: CRP (100.0%)> MPR (97.19%)>SSD (85.89%)> VR (78.50%)> MIP (27.88%).Conclusions:The MSCT joint multi-dimensional reconstruction techniques has a speciifc diagnostic value for the occult rib fractures, MSCT combined with MSCT CRP / MPR and VR, etc. could received a ideal diagnostic accuracy.