实用临床医药杂志
實用臨床醫藥雜誌
실용림상의약잡지
JOURNAL OF JIANGSU CLINICAL MEDICINE
2014年
5期
122-124
,共3页
分娩镇痛%舒芬太尼%低剂量%安全性
分娩鎮痛%舒芬太尼%低劑量%安全性
분면진통%서분태니%저제량%안전성
labor analgesia%sufentanil%low dose%safety
目的:探讨应用低剂量舒芬太尼对产妇行分娩镇痛的效果。方法将90例产妇随机分为观察组、对照 I 组及对照 II 组,每组30例。3组均采用舒芬太尼镇痛,对照 I 组用量为3μg,观察组用量为5μg,对照 II 组用量为7μg。比较3组的镇痛效果、产妇分娩结局、不良反应和新生儿状态等指标。结果对照 I 组的镇痛起效时间显著长于观察组和对照Ⅱ组(P <0.05),首剂持续时间显著短于观察组和对照Ⅱ组(P <0.05);镇痛前,3组患者的 VAS 评分无显著差异(P >0.05);镇痛后30、60 min,对照Ⅰ组的 VAS 显著高于其他2组(P <0.05);3组在顺产率、阴道助产率和剖宫产率方面比较无显著差异(P >0.05);对照Ⅰ组和观察组患者皮肤瘙痒、恶心呕吐、嗜睡、胎心改变等不良反应的发生率均显著低于对照Ⅱ组(P <0.05);对照Ⅰ组和观察组的新生儿于出生即刻的Apgar 评分显著高于对照Ⅱ组(P <0.05)。结论高、低剂量舒芬太尼均具有较好的分娩镇痛作用,而极低应用剂量则不能取得预期的效果。与高剂量舒芬太尼相比,低剂量舒芬太尼引发不良反应的概率较低,新生儿状态较好。
目的:探討應用低劑量舒芬太尼對產婦行分娩鎮痛的效果。方法將90例產婦隨機分為觀察組、對照 I 組及對照 II 組,每組30例。3組均採用舒芬太尼鎮痛,對照 I 組用量為3μg,觀察組用量為5μg,對照 II 組用量為7μg。比較3組的鎮痛效果、產婦分娩結跼、不良反應和新生兒狀態等指標。結果對照 I 組的鎮痛起效時間顯著長于觀察組和對照Ⅱ組(P <0.05),首劑持續時間顯著短于觀察組和對照Ⅱ組(P <0.05);鎮痛前,3組患者的 VAS 評分無顯著差異(P >0.05);鎮痛後30、60 min,對照Ⅰ組的 VAS 顯著高于其他2組(P <0.05);3組在順產率、陰道助產率和剖宮產率方麵比較無顯著差異(P >0.05);對照Ⅰ組和觀察組患者皮膚瘙癢、噁心嘔吐、嗜睡、胎心改變等不良反應的髮生率均顯著低于對照Ⅱ組(P <0.05);對照Ⅰ組和觀察組的新生兒于齣生即刻的Apgar 評分顯著高于對照Ⅱ組(P <0.05)。結論高、低劑量舒芬太尼均具有較好的分娩鎮痛作用,而極低應用劑量則不能取得預期的效果。與高劑量舒芬太尼相比,低劑量舒芬太尼引髮不良反應的概率較低,新生兒狀態較好。
목적:탐토응용저제량서분태니대산부행분면진통적효과。방법장90례산부수궤분위관찰조、대조 I 조급대조 II 조,매조30례。3조균채용서분태니진통,대조 I 조용량위3μg,관찰조용량위5μg,대조 II 조용량위7μg。비교3조적진통효과、산부분면결국、불량반응화신생인상태등지표。결과대조 I 조적진통기효시간현저장우관찰조화대조Ⅱ조(P <0.05),수제지속시간현저단우관찰조화대조Ⅱ조(P <0.05);진통전,3조환자적 VAS 평분무현저차이(P >0.05);진통후30、60 min,대조Ⅰ조적 VAS 현저고우기타2조(P <0.05);3조재순산솔、음도조산솔화부궁산솔방면비교무현저차이(P >0.05);대조Ⅰ조화관찰조환자피부소양、악심구토、기수、태심개변등불량반응적발생솔균현저저우대조Ⅱ조(P <0.05);대조Ⅰ조화관찰조적신생인우출생즉각적Apgar 평분현저고우대조Ⅱ조(P <0.05)。결론고、저제량서분태니균구유교호적분면진통작용,이겁저응용제량칙불능취득예기적효과。여고제량서분태니상비,저제량서분태니인발불량반응적개솔교저,신생인상태교호。
Objective To explore the effect of low dose sulfentanyl on labor analgesia. Methods 90 puerperas were randomly divided into observation group,control group I and control group Ⅱ,30 cases in each group.Sulfentanyl was used for labor analgesia in all the groups.The dose of sulfentanyl in the control group Ⅰ,the observation group and control group Ⅱ were 3 μg, 5 μg and 7μg respectively.Indexes such as analgesic efficacy,maternal birth outcomes,adverse re-actions and neonatal state were compared among three groups.Results The onset time of analge-sia in the control group Ⅰ was significantly longer than that in the observation group or the control group Ⅱ (P <0.05),while the first agent duration was significantly shorter than that in the ob-servation group or the control group Ⅱ (P <0.05);before the analgesia,there was no significant difference of VAS score among three groups (P >0.05);at the time of 30 and 60 minutes after analgesia,the VAS score of the control group I was significantly higher than that of the other two groups (P <0.05);there were no significant differences of the vaginal delivery rate,assistant vaginal delivery rate and cesarean section rate among the three groups (P >0.05);the incidence rates of the adverse reactions such as pruritus,nausea and vomiting,lethargy and fetal heart changes of the women in the control group Ⅰ and the observation group were significantly lower than those in the control group Ⅱ (P <0.05);the Apgar scores of the neonates in the control group Ⅰ and the observation group were significantly higher than that in the control group Ⅱ (P<0.05).Conclusion Efficacy of high or low dose sulfentanyl for labor analgesia is similar,while a very low dose sulfentanyl can not achieve the desired results.Compared with a high dose sulfen-tanyl,the adverse reactions probability induced by a low dose sufentanil is low and the neonatal state is better.