背景:对于老年股骨转子间骨折如何选择金属植入物,应根据不同患者的年龄、骨质疏松程度、围手术期状态、骨折类型等多因素进行考虑,制定个性化的治疗方案。目的:比较4种不同金属植入物内固定修复老年股骨转子间骨折的疗效。方法:回顾2009年9月至2012年9月收治的180例老年股骨转子间骨折患者,采用4种不同金属植入物内固定进行骨折修复,动力髋螺钉组、防旋型股骨近端髓内钉组、Gamma 钉组和解剖型髋动力带锁钢板组各45例。比较各组手术时间、出血量、住院时间、内固定后Harris评分、骨折愈合时间和并发症发生情况。结果与结论:解剖型髋动力带锁钢板组和防旋型股骨近端髓内钉组手术时间、出血量及住院时间均短于动力髋螺钉组和Gamma钉组(P <0.05),内固定后Harris评分优良率均高于动力髋螺钉组和Gamma 钉组(P <0.05),而前两组间差异无显著性意义(P>0.05)。解剖型髋动力带锁钢板组和防旋型股骨近端髓内钉组内固定后并发症发生率明显低于Gamma组和动力髋螺钉组(P<0.05)。提示解剖型髋动力带锁钢板和防旋型股骨近端髓内钉治疗老年转子间骨折内固定可靠、内固定后并发症少,是老年股骨转子间骨折植入物内固定治疗较为理想的选择。
揹景:對于老年股骨轉子間骨摺如何選擇金屬植入物,應根據不同患者的年齡、骨質疏鬆程度、圍手術期狀態、骨摺類型等多因素進行攷慮,製定箇性化的治療方案。目的:比較4種不同金屬植入物內固定脩複老年股骨轉子間骨摺的療效。方法:迴顧2009年9月至2012年9月收治的180例老年股骨轉子間骨摺患者,採用4種不同金屬植入物內固定進行骨摺脩複,動力髖螺釘組、防鏇型股骨近耑髓內釘組、Gamma 釘組和解剖型髖動力帶鎖鋼闆組各45例。比較各組手術時間、齣血量、住院時間、內固定後Harris評分、骨摺愈閤時間和併髮癥髮生情況。結果與結論:解剖型髖動力帶鎖鋼闆組和防鏇型股骨近耑髓內釘組手術時間、齣血量及住院時間均短于動力髖螺釘組和Gamma釘組(P <0.05),內固定後Harris評分優良率均高于動力髖螺釘組和Gamma 釘組(P <0.05),而前兩組間差異無顯著性意義(P>0.05)。解剖型髖動力帶鎖鋼闆組和防鏇型股骨近耑髓內釘組內固定後併髮癥髮生率明顯低于Gamma組和動力髖螺釘組(P<0.05)。提示解剖型髖動力帶鎖鋼闆和防鏇型股骨近耑髓內釘治療老年轉子間骨摺內固定可靠、內固定後併髮癥少,是老年股骨轉子間骨摺植入物內固定治療較為理想的選擇。
배경:대우노년고골전자간골절여하선택금속식입물,응근거불동환자적년령、골질소송정도、위수술기상태、골절류형등다인소진행고필,제정개성화적치료방안。목적:비교4충불동금속식입물내고정수복노년고골전자간골절적료효。방법:회고2009년9월지2012년9월수치적180례노년고골전자간골절환자,채용4충불동금속식입물내고정진행골절수복,동력관라정조、방선형고골근단수내정조、Gamma 정조화해부형관동력대쇄강판조각45례。비교각조수술시간、출혈량、주원시간、내고정후Harris평분、골절유합시간화병발증발생정황。결과여결론:해부형관동력대쇄강판조화방선형고골근단수내정조수술시간、출혈량급주원시간균단우동력관라정조화Gamma정조(P <0.05),내고정후Harris평분우량솔균고우동력관라정조화Gamma 정조(P <0.05),이전량조간차이무현저성의의(P>0.05)。해부형관동력대쇄강판조화방선형고골근단수내정조내고정후병발증발생솔명현저우Gamma조화동력관라정조(P<0.05)。제시해부형관동력대쇄강판화방선형고골근단수내정치료노년전자간골절내고정가고、내고정후병발증소,시노년고골전자간골절식입물내고정치료교위이상적선택。
BACKGROUND:The selection of metal implant for old patients with femoral intertrochanteric fracture should focus on patient’s age, osteoporotic degree, perioperative status and type of fracture. Individual therapeutic program should be made. OBJECTIVE:To compare the therapeutic effects of four types of metal implant fixation for femoral intertrochanteric fracture in old patients. METHODS:180 old patients with femoral intertrochanteric fractures treated from September 2009 to September 2012 were analyzed. Four kinds of metal implants were used for repair of fracture. There were 45 patients in the dynamic hip screw group, proximal femoral nail anti-rotation group, Gamma nail group and anatomical dynamic hip lock nickelclad group, separately. Operation time, blood loss, hospital time, Harris score after operation, fracture healing time and complications in different groups were compared. RESULTS AND CONCLUSION:Operation time and hospital time were shorter, and blood loss was fewer in the anatomical dynamic hip lock nickelclad group and proximal femoral nail anti-rotation group compared with the dynamic hip screw group and Gamma nail group (P<0.05), but the excellent and good rate of Harris score after operation was higher (P<0.05). No significant difference was detected between anatomical dynamic hip lock nickelclad group and proximal femoral nail anti-rotation group (P>0.05). The incidence of complications was significantly lower in the anatomical dynamic hip lock nickelclad group and proximal femoral nail anti-rotation group compared with the Gamma nail group and dynamic hip screw group (P<0.05). Results suggested that anatomical dynamic hip lock nickelclad and proximal femoral nail anti-rotation are reliable in treatment of intertrochanteric fracture in old patients, show less postoperative complications, and are ideal choices for implant fixation of femoral intertrochanteric fracture in old patients.