超声检查%脱垂%肛提肌%收缩功能
超聲檢查%脫垂%肛提肌%收縮功能
초성검사%탈수%항제기%수축공능
ultrasonography%prolapse%levator-ani-muscle%contractile-function
目的:探讨三维超声评估盆腔器官脱垂老年女性患者肛提肌收缩功能的应用价值。方法选择2011年7月至2013年2月该院妇科收治的盆腔器官脱垂老年女性患者58例,患者均接受经会阴三维超声检查及张力强度评分(Oxford Scale)。采集患者三维图像及数据,计算出膀胱颈移动度(D)、肛提肌裂孔长度(L)、水平成角(R)及面积(S)的变化值等参数数值,并对肛提肌Oxford Scale与三维超声参数的相关性进行分析。结果肛提肌Oxford Scale 0分2例,1分3例,2分10例,3分18例,4分20例,5分5例。三维超声参数D、L、R及 S值分别为(7.46±2.15)mm、(9.05±3.27)mm、(9.55±5.24)°和(16.43±2.58)%。对肛提肌 Oxford Scale与三维超声参数的相关性作进一步分析发现,肛提肌 Oxford Scale 与 S 值相关性最好(rs=0.77,P<0.01),其次为 L(rs=0.72,P<0.01)、R(rs=0.69,P<0.01)、D(rs=0.64,P<0.01)。结论三维超声能够较为客观地评估盆腔器官脱垂老年女性患者的肛提肌收缩功能。
目的:探討三維超聲評估盆腔器官脫垂老年女性患者肛提肌收縮功能的應用價值。方法選擇2011年7月至2013年2月該院婦科收治的盆腔器官脫垂老年女性患者58例,患者均接受經會陰三維超聲檢查及張力彊度評分(Oxford Scale)。採集患者三維圖像及數據,計算齣膀胱頸移動度(D)、肛提肌裂孔長度(L)、水平成角(R)及麵積(S)的變化值等參數數值,併對肛提肌Oxford Scale與三維超聲參數的相關性進行分析。結果肛提肌Oxford Scale 0分2例,1分3例,2分10例,3分18例,4分20例,5分5例。三維超聲參數D、L、R及 S值分彆為(7.46±2.15)mm、(9.05±3.27)mm、(9.55±5.24)°和(16.43±2.58)%。對肛提肌 Oxford Scale與三維超聲參數的相關性作進一步分析髮現,肛提肌 Oxford Scale 與 S 值相關性最好(rs=0.77,P<0.01),其次為 L(rs=0.72,P<0.01)、R(rs=0.69,P<0.01)、D(rs=0.64,P<0.01)。結論三維超聲能夠較為客觀地評估盆腔器官脫垂老年女性患者的肛提肌收縮功能。
목적:탐토삼유초성평고분강기관탈수노년녀성환자항제기수축공능적응용개치。방법선택2011년7월지2013년2월해원부과수치적분강기관탈수노년녀성환자58례,환자균접수경회음삼유초성검사급장력강도평분(Oxford Scale)。채집환자삼유도상급수거,계산출방광경이동도(D)、항제기렬공장도(L)、수평성각(R)급면적(S)적변화치등삼수수치,병대항제기Oxford Scale여삼유초성삼수적상관성진행분석。결과항제기Oxford Scale 0분2례,1분3례,2분10례,3분18례,4분20례,5분5례。삼유초성삼수D、L、R급 S치분별위(7.46±2.15)mm、(9.05±3.27)mm、(9.55±5.24)°화(16.43±2.58)%。대항제기 Oxford Scale여삼유초성삼수적상관성작진일보분석발현,항제기 Oxford Scale 여 S 치상관성최호(rs=0.77,P<0.01),기차위 L(rs=0.72,P<0.01)、R(rs=0.69,P<0.01)、D(rs=0.64,P<0.01)。결론삼유초성능구교위객관지평고분강기관탈수노년녀성환자적항제기수축공능。
Objective To probe the application value of the three-dimensional ultrasound in the evaluation of levator ani muscle contractile function in elderly female patients with pelvic organ prolapse.Methods 58 elderly female patients with pelvic organ pro-lapse in the gynecology department of our hospital from July 2011 to February 2013 were selected and received the transperineal three-dimensional ultrasound examination.The intensity evaluation was performed by the Oxford Scale.The three-dimensional ima-ges and data were collected for calculating the parameter values of the bladder neck mobility (D),levator hiatus length (L),horizon-tal angle (R)and area (S)changes,etc.The correlation between the Oxford Scale intensity score of levator ani muscle and the three-dimensional ultrasound parameters were further analyzed.Results The intensity scores of levator ani muscle by the Oxford Scale were as follows:0 points in 2 cases,1 points in 3 cases,2 points in 10 cases,3 points in 18 cases,4 points in 20 cases,5 points in 5 cases.Three-dimensional ultrasound parameters D,L,R and S values were (7.46±2.15)mm,(9.05±3.27)mm,(9.55±5.24)° and (16.43±2.58)%.Further analysis showed that the intensity score of the levator ani muscle by the Oxford Scale got the best correlation with the S value (rs= 0.77,P<0.01),followed by L (rs= 0.72,P<0.01),R (rs= 0.69,P<0.01 )and D (rs=0.64,P<0.01).Conclusion Three-dimensional ultrasound could be a more objective way to assess the levator ani muscle contrac-tile function in elderly female patients with pelvic organ prolapse.