移动电源与车辆
移動電源與車輛
이동전원여차량
MOVABLE POWER STATION & VEHICLE
2014年
3期
28-30
,共3页
低温启动%输油泵
低溫啟動%輸油泵
저온계동%수유빙
low temperature start%han d oil transfer pump
某型号电源配电车做环境试验,低温环境启动成功后停机。更换手打输油泵后,启动成功,工作正常。针对这种现象,根据低温启动的技术要求和原理、发电机组低温启动成功后停机故障树,分析原因,现场采取措施有效,实施效果良好,得到了同行的认可及推广。
某型號電源配電車做環境試驗,低溫環境啟動成功後停機。更換手打輸油泵後,啟動成功,工作正常。針對這種現象,根據低溫啟動的技術要求和原理、髮電機組低溫啟動成功後停機故障樹,分析原因,現場採取措施有效,實施效果良好,得到瞭同行的認可及推廣。
모형호전원배전차주배경시험,저온배경계동성공후정궤。경환수타수유빙후,계동성공,공작정상。침대저충현상,근거저온계동적기술요구화원리、발전궤조저온계동성공후정궤고장수,분석원인,현장채취조시유효,실시효과량호,득도료동행적인가급추엄。
The type power distribution vehicle for environmental testing , low temperature environment stop after a successful started .After change hands oil transfer pump , start the success , working properly .In this paper , ac-cording to this phenomenon , the technology requirements of the low temperature start and principle , generating set after the success of the low-temperature start stop the fault tree , analysis the reason , the measures to effectively , implementing effect is very good and get the approvl .