某石化公司加氢裂化装置换热器E-204和E-205出现腐蚀开裂问题,严重影响到加氢裂化装置的安全生产。本文介绍了换热器E-204和E-205腐蚀开裂情况,通过宏观检查、硬度检测、介质成分分析对换热器腐蚀进行失效分析,确定硫化氢应力腐蚀开裂为失效主要原因,并提出建议措施。
某石化公司加氫裂化裝置換熱器E-204和E-205齣現腐蝕開裂問題,嚴重影響到加氫裂化裝置的安全生產。本文介紹瞭換熱器E-204和E-205腐蝕開裂情況,通過宏觀檢查、硬度檢測、介質成分分析對換熱器腐蝕進行失效分析,確定硫化氫應力腐蝕開裂為失效主要原因,併提齣建議措施。
모석화공사가경열화장치환열기E-204화E-205출현부식개렬문제,엄중영향도가경열화장치적안전생산。본문개소료환열기E-204화E-205부식개렬정황,통과굉관검사、경도검측、개질성분분석대환열기부식진행실효분석,학정류화경응력부식개렬위실효주요원인,병제출건의조시。
Cracks found on heat exchangers E-204 and E-205 had a bad influence on safety production of catalytic cracking unit. This article introduced this corrosion and analysis was made by visual inspection, hardness testing, chemical composition analysis .Stress corrosion was the main reason for the failure. Some measures were suggested to avoid such corrosion.