空分装置因低压电系统故障而引起制氩系统循环液氩泵跳车,对制氩系统及整个精馏工况造成一定的影响。针对循环液氩泵跳车后出现的问题进行原因分析,介绍了相应的处理措施,并提出今后操作过程中应注意的若干事项。
空分裝置因低壓電繫統故障而引起製氬繫統循環液氬泵跳車,對製氬繫統及整箇精餾工況造成一定的影響。針對循環液氬泵跳車後齣現的問題進行原因分析,介紹瞭相應的處理措施,併提齣今後操作過程中應註意的若榦事項。
공분장치인저압전계통고장이인기제아계통순배액아빙도차,대제아계통급정개정류공황조성일정적영향。침대순배액아빙도차후출현적문제진행원인분석,개소료상응적처리조시,병제출금후조작과정중응주의적약간사항。
In air separation plant , the trouble of low-voltage electrical system causes mistrip of circulating liquid-argon pump of argon making system , which has some influences on argon making system and whole rectification condition .In connection with problems arisen after mistrip of liquid-argon pump , analysis of causes is carried out , relevant treatment measures are introduced , and matters needing attention in the next operation are suggested .