以某中学5层砖混结构宿舍的结构抗震检测鉴定为例,介绍了砖混结构房屋结构抗震鉴定的程序和内容,依据GB 50023-2009建筑抗震鉴定标准,对房屋结构抗震性能进行了综合评定与分析,给出了检测鉴定结论及需要抗震加固的建议。
以某中學5層磚混結構宿捨的結構抗震檢測鑒定為例,介紹瞭磚混結構房屋結構抗震鑒定的程序和內容,依據GB 50023-2009建築抗震鑒定標準,對房屋結構抗震性能進行瞭綜閤評定與分析,給齣瞭檢測鑒定結論及需要抗震加固的建議。
이모중학5층전혼결구숙사적결구항진검측감정위례,개소료전혼결구방옥결구항진감정적정서화내용,의거GB 50023-2009건축항진감정표준,대방옥결구항진성능진행료종합평정여분석,급출료검측감정결론급수요항진가고적건의。
Taking the structure seismic detection identification of 5 layers masonry-concrete dormitory of a middle school of as an example, this paper introduced the structure seismic identification procedures and contents of masonry-concrete structure housing, based on GB 50023-2009 Buildings Seismic Identification Standard, made comprehensively analysis and identification on seismic performance of building structures, gave the detection identification conclusions and seismic strengthening advices.