以即将并网发电的乡城水电站引水隧洞固结灌浆工程为研究对象。采用以地质雷达为主,声波检测和钻孔压水检测为辅的多种检测手段对多种围岩条件下的引水隧洞固结灌浆工程进行质量检测。通过对雷达检测数据的处理,归纳出缺陷段和密实段固结灌浆雷达检测特征图像,并通过钻孔压水试验和声波检测试验对雷达图像加以验证。结果表明:声波检测结果与地质雷达图像有着一定的联系。而钻孔压水试验得到的透水率与雷达图像没有明显的联系。在综合考虑了检测结果后,初步提出地质雷达检测固结灌浆的质量标准:检测抽样段长度应不少于总长度的5%;衬砌背后无空洞现象;不密实段长度占检测段长度比率小于15%,且位置分布不集中。凡符合上述要求,灌浆质量可评为合格。
以即將併網髮電的鄉城水電站引水隧洞固結灌漿工程為研究對象。採用以地質雷達為主,聲波檢測和鑽孔壓水檢測為輔的多種檢測手段對多種圍巖條件下的引水隧洞固結灌漿工程進行質量檢測。通過對雷達檢測數據的處理,歸納齣缺陷段和密實段固結灌漿雷達檢測特徵圖像,併通過鑽孔壓水試驗和聲波檢測試驗對雷達圖像加以驗證。結果錶明:聲波檢測結果與地質雷達圖像有著一定的聯繫。而鑽孔壓水試驗得到的透水率與雷達圖像沒有明顯的聯繫。在綜閤攷慮瞭檢測結果後,初步提齣地質雷達檢測固結灌漿的質量標準:檢測抽樣段長度應不少于總長度的5%;襯砌揹後無空洞現象;不密實段長度佔檢測段長度比率小于15%,且位置分佈不集中。凡符閤上述要求,灌漿質量可評為閤格。
이즉장병망발전적향성수전참인수수동고결관장공정위연구대상。채용이지질뢰체위주,성파검측화찬공압수검측위보적다충검측수단대다충위암조건하적인수수동고결관장공정진행질량검측。통과대뢰체검측수거적처리,귀납출결함단화밀실단고결관장뢰체검측특정도상,병통과찬공압수시험화성파검측시험대뢰체도상가이험증。결과표명:성파검측결과여지질뢰체도상유착일정적련계。이찬공압수시험득도적투수솔여뢰체도상몰유명현적련계。재종합고필료검측결과후,초보제출지질뢰체검측고결관장적질량표준:검측추양단장도응불소우총장도적5%;츤체배후무공동현상;불밀실단장도점검측단장도비솔소우15%,차위치분포불집중。범부합상술요구,관장질량가평위합격。
The paper took the consolidation grouting project of diversion tunnel at Xiangcheng hydropower sta -tion which will be the grid generation as research object .It mainly used geological radar , and assisted acoustic detection and borehole water pressure detection to detect the consolidation grouting project of diversion tunnel in the condition of a variety of surrounding rock .Through the treatment of radar detected data , the paper sum-marized the characteristic of image of the defect and density section of consolidation grouting of radar detec -tion,and verified the radar image through the tests of borehole water pressure and acoustic detection .The re-sult detected by acoustic wave has certain relation with the image of geological radar .The permeability rate gotten by the test of borehole water pressure has no clear link radar image .This paper presented the quality standards of consolidation grouting project by geological radar detection after comprehensively considering test result .The standards are that sampling length should be not less than 5%of the total length ,there is no empty phenomenon behind the lining .The grouting quality that is in accordance with the above requirements can be evaluated as qualified .