目的:研究双源CT双能量虚拟平扫技术在肝脏扫描中的应用价值。方法:对37例上腹部扫描患者行上腹部普通平扫及动脉期、门脉期双能量扫描。通过Liver VNC软件处理后,可以获得动脉期、门脉期虚拟平扫数据,并与普通平扫对比,比较其在平均CT值、信噪比( SNR)、病灶检出率、图像质量及辐射剂量上的差异。结果:虚拟平扫和普通平扫在病灶检出率上无明显差异(P>0.05)。虚拟平扫肝脏CT值高于普通平扫(P<0.05);虚拟平扫图像SNR高于普通平扫(P<0.05)。两组虚拟平扫之间差异无统计学意义(P>0.05)。虚拟平扫的图像质量均可满足临床诊断需求。应用虚拟平扫,可取消普通平扫,辐射剂量可降低34%。结论:双源CT的虚拟平扫技术在保证图像质量的前提下降低了辐射剂量,可取代普通平扫,具有临床应用的潜力。
目的:研究雙源CT雙能量虛擬平掃技術在肝髒掃描中的應用價值。方法:對37例上腹部掃描患者行上腹部普通平掃及動脈期、門脈期雙能量掃描。通過Liver VNC軟件處理後,可以穫得動脈期、門脈期虛擬平掃數據,併與普通平掃對比,比較其在平均CT值、信譟比( SNR)、病竈檢齣率、圖像質量及輻射劑量上的差異。結果:虛擬平掃和普通平掃在病竈檢齣率上無明顯差異(P>0.05)。虛擬平掃肝髒CT值高于普通平掃(P<0.05);虛擬平掃圖像SNR高于普通平掃(P<0.05)。兩組虛擬平掃之間差異無統計學意義(P>0.05)。虛擬平掃的圖像質量均可滿足臨床診斷需求。應用虛擬平掃,可取消普通平掃,輻射劑量可降低34%。結論:雙源CT的虛擬平掃技術在保證圖像質量的前提下降低瞭輻射劑量,可取代普通平掃,具有臨床應用的潛力。
목적:연구쌍원CT쌍능량허의평소기술재간장소묘중적응용개치。방법:대37례상복부소묘환자행상복부보통평소급동맥기、문맥기쌍능량소묘。통과Liver VNC연건처리후,가이획득동맥기、문맥기허의평소수거,병여보통평소대비,비교기재평균CT치、신조비( SNR)、병조검출솔、도상질량급복사제량상적차이。결과:허의평소화보통평소재병조검출솔상무명현차이(P>0.05)。허의평소간장CT치고우보통평소(P<0.05);허의평소도상SNR고우보통평소(P<0.05)。량조허의평소지간차이무통계학의의(P>0.05)。허의평소적도상질량균가만족림상진단수구。응용허의평소,가취소보통평소,복사제량가강저34%。결론:쌍원CT적허의평소기술재보증도상질량적전제하강저료복사제량,가취대보통평소,구유림상응용적잠력。
Objective:To evaluate the diagnostic value of applying virtual non-contrast scanning to liver lesions with dual-source,dual-energy computed tomography( CT) .Methods:Conventional non-enhanced abdominal CT scanning was performed in 37 patients,followed by scans during the hepatic arterial phase and portal phase with dual-source in dual-energy mode.The images were generated with the built-in liver VNC program for the raw data during the hepatic arterial phase and portal phase in virtual non-contrasted manner,and the previous data were compared with those obtained by conventional non-en-hanced scans regarding the differences of mean CT value,signal-to-noise ratio(SNR),focal lesions detected,imaging quality and radiation dose.Results:Although the focal lesions detected remained relatively comparable by either virtual or conventional non-contrasted scanning(P>0.05),yet the CT Hu values for liver were higher on virtual non-contrast CT images than the conventional counterparts(P<0.05),and virtual non-contrast CT also led to better SNR(P<0.05).Scans during the hepatic arterial phase and portal phase suggested no difference with the lesions detected(P>0.05),and generated sim-ilar diagnostic imaging quality .Virtual non-contrast CT,a substitute for the conventional non-enhanced tomography,was capable of reducing the radiation dose by 34%.Conclusion:Dual-source dual-energy CT may take the place of the conventional non-enhanced CT and be in wider clinical implications ,for it can reduce the level of ionizing radiation by generating favorable imaging quality .