目的 比较自体封闭式巩膜引流术和Ahmed青光眼阀植入术治疗难治性青光眼的临床疗效.方法 对2006年1月至2012年1月在淮南市晨光眼科医院就诊的难治性青光眼患者49只眼分为自体封闭式巩膜引流术组(25只眼)和Ahmed青光眼阀植入术组(24只眼).于术后对两组患者的眼压和手术并发症进行观察.结果 自体封闭式巩膜引流术组和Ahmed青光眼阀植入术组术前、术后1周和1个月时眼压比较,差异无统计学意义(P>0.05).术后6个月时自体封闭式巩膜引流术组眼压显著低于Ahmed青光眼阀植入术组差异有统计学意义(P<0.05).自体封闭式巩膜引流术组手术并发症的发生率显著低于Ahmed青光眼阀植入术组,差异有统计学意义(P<0.05).结论 自体封闭式巩膜引流术可有效控制难治性青光眼的眼压,且手术并发症较少.
目的 比較自體封閉式鞏膜引流術和Ahmed青光眼閥植入術治療難治性青光眼的臨床療效.方法 對2006年1月至2012年1月在淮南市晨光眼科醫院就診的難治性青光眼患者49隻眼分為自體封閉式鞏膜引流術組(25隻眼)和Ahmed青光眼閥植入術組(24隻眼).于術後對兩組患者的眼壓和手術併髮癥進行觀察.結果 自體封閉式鞏膜引流術組和Ahmed青光眼閥植入術組術前、術後1週和1箇月時眼壓比較,差異無統計學意義(P>0.05).術後6箇月時自體封閉式鞏膜引流術組眼壓顯著低于Ahmed青光眼閥植入術組差異有統計學意義(P<0.05).自體封閉式鞏膜引流術組手術併髮癥的髮生率顯著低于Ahmed青光眼閥植入術組,差異有統計學意義(P<0.05).結論 自體封閉式鞏膜引流術可有效控製難治性青光眼的眼壓,且手術併髮癥較少.
목적 비교자체봉폐식공막인류술화Ahmed청광안벌식입술치료난치성청광안적림상료효.방법 대2006년1월지2012년1월재회남시신광안과의원취진적난치성청광안환자49지안분위자체봉폐식공막인류술조(25지안)화Ahmed청광안벌식입술조(24지안).우술후대량조환자적안압화수술병발증진행관찰.결과 자체봉폐식공막인류술조화Ahmed청광안벌식입술조술전、술후1주화1개월시안압비교,차이무통계학의의(P>0.05).술후6개월시자체봉폐식공막인류술조안압현저저우Ahmed청광안벌식입술조차이유통계학의의(P<0.05).자체봉폐식공막인류술조수술병발증적발생솔현저저우Ahmed청광안벌식입술조,차이유통계학의의(P<0.05).결론 자체봉폐식공막인류술가유효공제난치성청광안적안압,차수술병발증교소.
Objective To compare the clinical effects of autologous and enclosed scleral shunt and glaucoma valve implantation in patients with refractory glaucoma.Methods 49 eyes in refractory glaucoma patients were randomized to undergo the autologous and enclosed scleral shunt and the glaucoma valve implantation.Then the intraocular pressure and operative complications were observed postoperatively.Results There were no significant differences between the autologous and enclosed scleral shunt group and the glaucoma valve implantation group in the intraocular pressure preoperatively and 1 week,1 month after operation(P >0.05).Compared with the glaucoma valve implantation group,the intraocular pressure in the autologous and enclosed scleral shunt group was significantly decreased at 6 months after operation (P <0.05).The rate of operative complications was also significantly decreased postoperatively in the autologous and enclosed scleral shunt group (P <0.05).Conclusion The autologous and enclosed scleral shuntcan effectively reduce the intraocular pressure in patients with refractory glaucoma with less complications.