当煤矿发生火灾后,对其进行爆炸危险性分析对于指导火灾救灾非常重要。通过对科瓦德爆炸三角形进行改造,构造了一个以时间为横坐标、爆炸危险性为纵坐标的混合气体爆炸危险性连续分析图。使用该方法对矿井火灾救灾过程中的实测数据进行处理,并将分析结果与爆炸四方图、爆炸三角形(美国)的分析结果进行对比,结果表明:使用混合气体爆炸危险性连续分析图,不仅可以有效地对多种可燃气体与多种惰气的混合气体进行爆炸危险性判断,还可以清晰地显示矿井火区爆炸危险性的变化趋势,便于对混合气体爆炸危险性进行长期连续分析。
噹煤礦髮生火災後,對其進行爆炸危險性分析對于指導火災救災非常重要。通過對科瓦德爆炸三角形進行改造,構造瞭一箇以時間為橫坐標、爆炸危險性為縱坐標的混閤氣體爆炸危險性連續分析圖。使用該方法對礦井火災救災過程中的實測數據進行處理,併將分析結果與爆炸四方圖、爆炸三角形(美國)的分析結果進行對比,結果錶明:使用混閤氣體爆炸危險性連續分析圖,不僅可以有效地對多種可燃氣體與多種惰氣的混閤氣體進行爆炸危險性判斷,還可以清晰地顯示礦井火區爆炸危險性的變化趨勢,便于對混閤氣體爆炸危險性進行長期連續分析。
당매광발생화재후,대기진행폭작위험성분석대우지도화재구재비상중요。통과대과와덕폭작삼각형진행개조,구조료일개이시간위횡좌표、폭작위험성위종좌표적혼합기체폭작위험성련속분석도。사용해방법대광정화재구재과정중적실측수거진행처리,병장분석결과여폭작사방도、폭작삼각형(미국)적분석결과진행대비,결과표명:사용혼합기체폭작위험성련속분석도,불부가이유효지대다충가연기체여다충타기적혼합기체진행폭작위험성판단,환가이청석지현시광정화구폭작위험성적변화추세,편우대혼합기체폭작위험성진행장기련속분석。
After the coal mine fire, the explosion risk analysis on the mixed gases is very important to the guidance of fire disaster relief. Based on Coward explosive triangle, a continuous analysis diagram with the time as the abscissa and the explosion risk as the ordinate for explosion risk of the mixed gases in fire area was constructed. The data collected from the mine fire disaster relief process were processed with this method and comparison was made on the analysis results obtained by the continuous analysis diagram of explosion risk of the mixed gases with those obtained by the explosion quartet figure and U. S. explosive triangle, the results showed that the continuous analysis diagram of explosion risk of the mixed gases can not only be used to effectively judge the explosion risk of the mixed gases of various combustible gases and inert gases, but also clearly show the change trend of the explosion risk in mine fire area, this is convenient for the long-term continuous analysis of the explosion risk of mixed gases.