为探究某种阻尼材料对高速列车铝型材地板的减振降噪效果,以波纹状铝型材为基板,先后对其喷涂厚度为2 mm和4 mm的阻尼层,并在隔声室中进行空气声隔声及结构振动声辐射的测试及比对分析。结果显示,随阻尼层厚度的增加,铝型材的空气声隔声效果增加,尤其在500 Hz之后的中高频段;其中,2 mm阻尼层能在铝型材裸板的基础上使计权隔声量提高4.5 dB,阻尼层厚度增至4 mm,计权隔声量再提高2.4 dB。在100 Hz~250 Hz,2 mm阻尼层对降低铝型材的振动声辐射水平起反作用,而4 mm阻尼层能够起到一定作用;在315 Hz~400 Hz,阻尼层厚度对其振动声辐射几乎没有影响;500 Hz以上,随阻尼层厚度的增加,铝型材振动声辐射水平大大降低,其中,500 Hz、1250 Hz和3150 Hz三个频段的降低量最为显著。
為探究某種阻尼材料對高速列車鋁型材地闆的減振降譟效果,以波紋狀鋁型材為基闆,先後對其噴塗厚度為2 mm和4 mm的阻尼層,併在隔聲室中進行空氣聲隔聲及結構振動聲輻射的測試及比對分析。結果顯示,隨阻尼層厚度的增加,鋁型材的空氣聲隔聲效果增加,尤其在500 Hz之後的中高頻段;其中,2 mm阻尼層能在鋁型材裸闆的基礎上使計權隔聲量提高4.5 dB,阻尼層厚度增至4 mm,計權隔聲量再提高2.4 dB。在100 Hz~250 Hz,2 mm阻尼層對降低鋁型材的振動聲輻射水平起反作用,而4 mm阻尼層能夠起到一定作用;在315 Hz~400 Hz,阻尼層厚度對其振動聲輻射幾乎沒有影響;500 Hz以上,隨阻尼層厚度的增加,鋁型材振動聲輻射水平大大降低,其中,500 Hz、1250 Hz和3150 Hz三箇頻段的降低量最為顯著。
위탐구모충조니재료대고속열차려형재지판적감진강조효과,이파문상려형재위기판,선후대기분도후도위2 mm화4 mm적조니층,병재격성실중진행공기성격성급결구진동성복사적측시급비대분석。결과현시,수조니층후도적증가,려형재적공기성격성효과증가,우기재500 Hz지후적중고빈단;기중,2 mm조니층능재려형재라판적기출상사계권격성량제고4.5 dB,조니층후도증지4 mm,계권격성량재제고2.4 dB。재100 Hz~250 Hz,2 mm조니층대강저려형재적진동성복사수평기반작용,이4 mm조니층능구기도일정작용;재315 Hz~400 Hz,조니층후도대기진동성복사궤호몰유영향;500 Hz이상,수조니층후도적증가,려형재진동성복사수평대대강저,기중,500 Hz、1250 Hz화3150 Hz삼개빈단적강저량최위현저。
In order to clearly understand the effect of sprayed-damping on vibration and noise reduction of section aluminum floor of high-speed trains, a corrugated aluminum is used as the substrate and sprayed with 2 mm and 4 mm thick damping layers on it respectively. Then, the tests of the sound insulation, structural vibration and noise radiation are conducted in a laboratory. The test results show that as the thickness of the damping layer increases, the sound insulation effect increases, especially in the medium and high frequency range above 500 Hz. Sticking 2 mm thick damping layer on the corrugated aluminum floor can increase the weighted sound insulation by 4.5 dB compared with the corrugated aluminum floor without damping. When the thickness of the damping layer increases to 4 mm, the weighted sound insulation increases by 2.4 dB in comparison with 2 mm thick damping layer. In the range of 100 Hz~250 Hz, the 2 mm thick damping layer has negative effect on the reduction of vibration and noise radiation, but 4 mm thick damping layer has somewhat effect on noise and vibration reduction. In the frequency range from 315 Hz to 400 Hz, the damping layers of 2 mm and 4mm thicknesses have little sound insulation effect. When the frequency exceeds 500 Hz, with the increasing of the damping layer thickness, the vibration and noise radiation level of the section aluminum can be remarkably reduced, especially for the frequencies of 500 Hz, 1 250 Hz and 3 150 Hz.