介绍了腐蚀监测技术的两种主要形式(电阻探针法及试片失重法)在室内静态污水介质中的对比应用试验。在相同腐蚀介质的条件下,电阻探针监测腐蚀速率是腐蚀挂片腐蚀速率的4.89倍。当电阻探针测量元件发生严重局部腐蚀时,其测出的腐蚀速率会明显升高。
介紹瞭腐蝕鑑測技術的兩種主要形式(電阻探針法及試片失重法)在室內靜態汙水介質中的對比應用試驗。在相同腐蝕介質的條件下,電阻探針鑑測腐蝕速率是腐蝕掛片腐蝕速率的4.89倍。噹電阻探針測量元件髮生嚴重跼部腐蝕時,其測齣的腐蝕速率會明顯升高。
개소료부식감측기술적량충주요형식(전조탐침법급시편실중법)재실내정태오수개질중적대비응용시험。재상동부식개질적조건하,전조탐침감측부식속솔시부식괘편부식속솔적4.89배。당전조탐침측량원건발생엄중국부부식시,기측출적부식속솔회명현승고。
This paper introduced two forms of Corrosion Monitoring techniques (Electrical Resistance and Corrosion Coupons) and compared the corrosion rate in lab. The corrosion rate of ER probe is 4.89 times more than that of Corrosion Coupons. When there was pitting corrosion on the surface of ER probe element, the corrosion rate increased significantly.