化肥工业
化肥工業
화비공업
JOURNAL OF THE CHEMICAL FERTILIZER INDUSTRY
2014年
4期
39-41
,共3页
双加压法%硝酸%水冷器%优化改造
雙加壓法%硝痠%水冷器%優化改造
쌍가압법%초산%수랭기%우화개조
dual-pressure process%nitric acid%water cooler%optimization and renovation
介绍了双加压法硝酸装置低压反应水冷器的运行工况及特性,分析了水冷器腐蚀的原因主要为温差应力腐蚀、高温冷凝稀硝酸冲刷和Cl-聚集的应力腐蚀。针对腐蚀原因,提出了采用内孔焊先进制造工艺、改变设备布置形式等优化改造措施,能够有效解决目前存在易腐蚀的问题。
介紹瞭雙加壓法硝痠裝置低壓反應水冷器的運行工況及特性,分析瞭水冷器腐蝕的原因主要為溫差應力腐蝕、高溫冷凝稀硝痠遲刷和Cl-聚集的應力腐蝕。針對腐蝕原因,提齣瞭採用內孔銲先進製造工藝、改變設備佈置形式等優化改造措施,能夠有效解決目前存在易腐蝕的問題。
개소료쌍가압법초산장치저압반응수랭기적운행공황급특성,분석료수랭기부식적원인주요위온차응력부식、고온냉응희초산충쇄화Cl-취집적응력부식。침대부식원인,제출료채용내공한선진제조공예、개변설비포치형식등우화개조조시,능구유효해결목전존재역부식적문제。
The operation conditions and characteristics of low-pressure reactor water cooler for nitric acid unit is introduced , and the causes for corrosion of the water cooler is analyzed , they are differential temperature stress corrosion , high temperature condense dilute nitric acid erosion and stress corrosion of Cl - gathering .Based on corrosion causes , optimization and renovation measures are proposed , including using advanced inner hole welding technology , changing layout of equipment and so on, these can solved corrosion problems effectively .