研究用高压釜消解-ICP-OES测定印刷线路板中重金属元素Pb,Cd及S的含量。结果表明,方法灵敏、快速、准确、操作方便,实用性强。Pb,Cd,S的回收率在96.0%~97.8%之间,相对标准偏差RSD<5%。
研究用高壓釜消解-ICP-OES測定印刷線路闆中重金屬元素Pb,Cd及S的含量。結果錶明,方法靈敏、快速、準確、操作方便,實用性彊。Pb,Cd,S的迴收率在96.0%~97.8%之間,相對標準偏差RSD<5%。
연구용고압부소해-ICP-OES측정인쇄선로판중중금속원소Pb,Cd급S적함량。결과표명,방법령민、쾌속、준학、조작방편,실용성강。Pb,Cd,S적회수솔재96.0%~97.8%지간,상대표준편차RSD<5%。
The determination of Pb ,Cd and S content in coating drier by Inductively Coupled Plasma-Optical Emission Spectrometer(ICP-OES)with high press digustion is investigated. The result s show that this method is delicacy ,rapid , accurate ,easy to operate and practicable. The recoveries for the three element s are in the range of 96.0%~97.8%and relative standard deviation<5%is achieved.