【目的】探讨低浓度碘对比剂配合低电压的前瞻性心电门控扫描在冠状动脉CT血管造影(CTA)检查中的应用价值。【方法】连续收集体质量指数(BM I)小于24 kg/m2的临床疑诊冠心病者59例,随机分为3组:A组(25例)及B组(14例)分别应用270 mgI/mL及320 mgI/mL的碘对比剂,管电压分别为80 kV和100 kV ,C组(20例)应用370 mgI/mL碘对比剂,管电压为120 kV。三组所有病例均采用心电门控触发序列扫描,有效辐射剂量(ED),测量主动脉根部的平均CT值,并对所有病例的冠状动脉CTA图像质量进行评分。【结果】A组、B组和C组的ED分别为(2.00±0.56)、(2.51±0.52)及(4.17±1.55)mSv,三组间两两比较均有显著性差异(P <0.05)。A、B、C组主动脉根部增强程度分别为(486.8±113.980)HU、(407.43±83.63) HU、(439.73±72.12) HU ,经统计分析,仅A、B两组比较有统计学意义( t =2.28,P <0.05)。A组、B组及C组分别显示225个、126个和180个冠脉节段,图像优秀率分别为94.67%、89.68%和95.56%,经统计学分析,B、C比较有统计学意义(χ2值为4.00,P <0.05),A、B组和 A、C组比较均无统计学差异(χ2值分别为3.03和0.17,均 P >0.05)。【结论】对标准及低体质量人群应用低浓度碘对比剂同时采用低管电压冠状动脉CTA扫描,能够在获得满足诊断图像质量的前提下,大幅度降低碘注射量及辐射剂量。
【目的】探討低濃度碘對比劑配閤低電壓的前瞻性心電門控掃描在冠狀動脈CT血管造影(CTA)檢查中的應用價值。【方法】連續收集體質量指數(BM I)小于24 kg/m2的臨床疑診冠心病者59例,隨機分為3組:A組(25例)及B組(14例)分彆應用270 mgI/mL及320 mgI/mL的碘對比劑,管電壓分彆為80 kV和100 kV ,C組(20例)應用370 mgI/mL碘對比劑,管電壓為120 kV。三組所有病例均採用心電門控觸髮序列掃描,有效輻射劑量(ED),測量主動脈根部的平均CT值,併對所有病例的冠狀動脈CTA圖像質量進行評分。【結果】A組、B組和C組的ED分彆為(2.00±0.56)、(2.51±0.52)及(4.17±1.55)mSv,三組間兩兩比較均有顯著性差異(P <0.05)。A、B、C組主動脈根部增彊程度分彆為(486.8±113.980)HU、(407.43±83.63) HU、(439.73±72.12) HU ,經統計分析,僅A、B兩組比較有統計學意義( t =2.28,P <0.05)。A組、B組及C組分彆顯示225箇、126箇和180箇冠脈節段,圖像優秀率分彆為94.67%、89.68%和95.56%,經統計學分析,B、C比較有統計學意義(χ2值為4.00,P <0.05),A、B組和 A、C組比較均無統計學差異(χ2值分彆為3.03和0.17,均 P >0.05)。【結論】對標準及低體質量人群應用低濃度碘對比劑同時採用低管電壓冠狀動脈CTA掃描,能夠在穫得滿足診斷圖像質量的前提下,大幅度降低碘註射量及輻射劑量。
【목적】탐토저농도전대비제배합저전압적전첨성심전문공소묘재관상동맥CT혈관조영(CTA)검사중적응용개치。【방법】련속수집체질량지수(BM I)소우24 kg/m2적림상의진관심병자59례,수궤분위3조:A조(25례)급B조(14례)분별응용270 mgI/mL급320 mgI/mL적전대비제,관전압분별위80 kV화100 kV ,C조(20례)응용370 mgI/mL전대비제,관전압위120 kV。삼조소유병례균채용심전문공촉발서렬소묘,유효복사제량(ED),측량주동맥근부적평균CT치,병대소유병례적관상동맥CTA도상질량진행평분。【결과】A조、B조화C조적ED분별위(2.00±0.56)、(2.51±0.52)급(4.17±1.55)mSv,삼조간량량비교균유현저성차이(P <0.05)。A、B、C조주동맥근부증강정도분별위(486.8±113.980)HU、(407.43±83.63) HU、(439.73±72.12) HU ,경통계분석,부A、B량조비교유통계학의의( t =2.28,P <0.05)。A조、B조급C조분별현시225개、126개화180개관맥절단,도상우수솔분별위94.67%、89.68%화95.56%,경통계학분석,B、C비교유통계학의의(χ2치위4.00,P <0.05),A、B조화 A、C조비교균무통계학차이(χ2치분별위3.03화0.17,균 P >0.05)。【결론】대표준급저체질량인군응용저농도전대비제동시채용저관전압관상동맥CTA소묘,능구재획득만족진단도상질량적전제하,대폭도강저전주사량급복사제량。
To explore the value of low concentration iodine contrast medium combined with low voltage in prospective ECG-trigger gated coronary artery CT angiography (CTA) .[Methods] Totally 59 patients [body mass index(BMI)<24 kg/m2 ] suspected as coronary heart disease were collected continuously and divided into 3 groups randomly .Group A( n=25) and group B( n=14) received 270 mgI/mL and 320 mgI/mL contrast medium and 80 kV and 100 kV tube voltage respectively ,while group C( n = 20) received 370mgI/mL contrast medium and 120 kV tube voltage . Prospective ECG-trigger sequence scan was performed in all patients of 3 groups .The effective radiation dose(ED) was recorded .Mean CT value of aorta root was measured .CTA image quality of all patients was scored .[Results] The ED in group A ,B and C were (2 .00 ± 0 .56) ,(2 .51 ± 0 .52) and (4 .17 ± 1 .55)mSv respectively ,and there were significant differences among 3 groups( P <0 .05) .The enhanced degree of aortic root in group A ,B and C were (486 .8 ± 113 .98) ,(407 .43 ± 83 .63) and (439 .73 ± 72 .12)HU re-spectively ,and there was significant difference only between group A and group B ( t =2 .28 ,P <0 .05) .Group A ,B and C showed 225 ,126 and 126 coronary segments ,respectively .The excellent rate of group A ,B and C were 94 .67% ,89 .68% and 94 .67% respectively ,and there was significant difference between group B and C (χ2= 4 .00 ,P<0 .05) ,but there was no significant difference between group A and group B or between group A and group C(χ2 = 4 .00 and 0 .17 ,all P >0 .05) .[Conclusion] Low concentration iodine contrast medium combined with low tube voltage in coronary artery CTA scan for standard and low body weight people can obtain satisfactory diagnosis image quality and reduce injection dose and ED of iodine obviously .