为现场测量大型透明件的透光率和雾度,提出了基于双积分球结构的测量和系统参数标定方案,并设计研制了相应的透光率和雾度测量装置。该装置通过六维机械调整装置完成光路调整,基于L ED光源的照明准直系统产生调制平行光,最后采用双积分球结构的探测接收装置并结合锁相放大技术,实现光电信号的解调。测试结果表明,该装置对透光率测量的绝对误差不超过1%,对雾度测量的绝对误差不超过0.3%,符合工程应用对系统测量精度提出的要求。另一方面,装置具有很好的重复性,其对透光率和雾度测量的相对标准差分别为0.06%和0.05%。
為現場測量大型透明件的透光率和霧度,提齣瞭基于雙積分毬結構的測量和繫統參數標定方案,併設計研製瞭相應的透光率和霧度測量裝置。該裝置通過六維機械調整裝置完成光路調整,基于L ED光源的照明準直繫統產生調製平行光,最後採用雙積分毬結構的探測接收裝置併結閤鎖相放大技術,實現光電信號的解調。測試結果錶明,該裝置對透光率測量的絕對誤差不超過1%,對霧度測量的絕對誤差不超過0.3%,符閤工程應用對繫統測量精度提齣的要求。另一方麵,裝置具有很好的重複性,其對透光率和霧度測量的相對標準差分彆為0.06%和0.05%。
위현장측량대형투명건적투광솔화무도,제출료기우쌍적분구결구적측량화계통삼수표정방안,병설계연제료상응적투광솔화무도측량장치。해장치통과륙유궤계조정장치완성광로조정,기우L ED광원적조명준직계통산생조제평행광,최후채용쌍적분구결구적탐측접수장치병결합쇄상방대기술,실현광전신호적해조。측시결과표명,해장치대투광솔측량적절대오차불초과1%,대무도측량적절대오차불초과0.3%,부합공정응용대계통측량정도제출적요구。령일방면,장치구유흔호적중복성,기대투광솔화무도측량적상대표준차분별위0.06%화0.05%。
In order to obtain the luminous transmittance and haze of large transparent compo-nent in field ,measurement scheme and method of calibration of system parameters based on double integrating spheres structure were presented .Furthermore the testing device was de-signed and manufactured .The optical path of device was adjusted by 6 dimensional mechanical adjustment structure firstly .Then the modulated directional light was generated by the illumi-nation and collimation system based on LED source . Finally by using the detective part of double integrating spheres structure and the phase-locked amplifier technology ,the signal was demodulated accordingly .T he testing result show s that ,by using the device ,the absolute er-ror of light transmittance is no more than 1% and that of haze is no more than 0 .3% ,w hich meet the precision requirement of engineering application .Moreover the repeatability of device was also good .The relative standard deviation of luminous transmittance and haze was 0 .06 %and 0 .05% respectively .