西南交通大学学报
西南交通大學學報
서남교통대학학보
JOURNAL OF SOUTHWEST JIAOTONG UNIVERSITY
2014年
5期
875-881
,共7页
郭冀岭%肖建%邱忠才%罗鹏
郭冀嶺%肖建%邱忠纔%囉鵬
곽기령%초건%구충재%라붕
七相感应电机%矢量控制%空间矢量脉宽调制%消除谐波
七相感應電機%矢量控製%空間矢量脈寬調製%消除諧波
칠상감응전궤%시량공제%공간시량맥관조제%소제해파
seven-phase induction motor%vector control%SVPWM%harmonic elimination
为了实现对七相感应电机磁链和转矩控制,同时消除定子谐波电流,根据减小空间解耦模型谐波子空间中合成电压矢量的原理,提出了3种消除定子谐波电流的方法,即3次谐波子空间合成矢量为0的SVPWM (space vector pulse width module)A法、3次及5次谐波子空间合成矢量同时为0的SVPWM B法和通过电机闭环控制的UVM (unified voltage module)C法.采用负载调速实验验证了3种控制方法对七相感应电机磁链和转矩的控制效果.结果表明:SVPWM A法和SVPWM B法,在调制深度和转速调节过程中,依靠调整施加矢量顺序和作用时间来实现消谐,效果不理想;UVM C法通过增加谐波子空间电压为0的约束条件,实现闭环控制,消除谐波电流效果较好,在基波含量为52.5 dB情况下,3次和5次谐波含量很低,仅为17.8和9.8 dB.
為瞭實現對七相感應電機磁鏈和轉矩控製,同時消除定子諧波電流,根據減小空間解耦模型諧波子空間中閤成電壓矢量的原理,提齣瞭3種消除定子諧波電流的方法,即3次諧波子空間閤成矢量為0的SVPWM (space vector pulse width module)A法、3次及5次諧波子空間閤成矢量同時為0的SVPWM B法和通過電機閉環控製的UVM (unified voltage module)C法.採用負載調速實驗驗證瞭3種控製方法對七相感應電機磁鏈和轉矩的控製效果.結果錶明:SVPWM A法和SVPWM B法,在調製深度和轉速調節過程中,依靠調整施加矢量順序和作用時間來實現消諧,效果不理想;UVM C法通過增加諧波子空間電壓為0的約束條件,實現閉環控製,消除諧波電流效果較好,在基波含量為52.5 dB情況下,3次和5次諧波含量很低,僅為17.8和9.8 dB.
위료실현대칠상감응전궤자련화전구공제,동시소제정자해파전류,근거감소공간해우모형해파자공간중합성전압시량적원리,제출료3충소제정자해파전류적방법,즉3차해파자공간합성시량위0적SVPWM (space vector pulse width module)A법、3차급5차해파자공간합성시량동시위0적SVPWM B법화통과전궤폐배공제적UVM (unified voltage module)C법.채용부재조속실험험증료3충공제방법대칠상감응전궤자련화전구적공제효과.결과표명:SVPWM A법화SVPWM B법,재조제심도화전속조절과정중,의고조정시가시량순서화작용시간래실현소해,효과불이상;UVM C법통과증가해파자공간전압위0적약속조건,실현폐배공제,소제해파전류효과교호,재기파함량위52.5 dB정황하,3차화5차해파함량흔저,부위17.8화9.8 dB.
In order to control the flux and torque and eliminate harmonic status currents of seven-phase induction motors simultaneously,three methods were proposed according to the principle of reducing the harmonic subspace composite voltage vectors in the space decomposition model. These methods included the space vector pulse width module (SVPWM)A where the composite voltage vector of the 3rd harmonic subspace is zero,the SVPWM B where the composite voltage vector of the 3rd or the 5th harmonic subspace is zero,and the unified voltage module (UVM)C that adopts a closed-loop motor control strategy. Speed-regulating experiments were then performed to verify the efficiency of the three methods in control of the flux and torque. The results show that the performance on harmonic currents elimination using SVPWM A or SVPWM B is not satisfying,since only the action time and sequence of voltage vectors are adjusted while the modulation depth and motor speed are changing continuously. However,a closed loop control of motor is realized under the constraint that harmonic space voltage is zero;therefore,the harmonic currents were eliminated remarkably using UVM C. Compared with the fundamental content (52. 5 dB),the 3rd and 5th harmonic contents are very small, only 17. 8 and 9. 8 dB,respectively.