对脱硫 CMES 多发性故障的产生原因进行了分析研究,探讨了负荷、煤种波动对 CEMS 故障率的影响,开展CEMS 故障时长对比分析。结果发现干法脱硫异常数据时长远低于湿法脱硫,无 GGH 脱硫 CEMS 故障率远高于有GGH,高负荷时段、燃用高灰分煤种也使得 CEMS 的故障率提高。
對脫硫 CMES 多髮性故障的產生原因進行瞭分析研究,探討瞭負荷、煤種波動對 CEMS 故障率的影響,開展CEMS 故障時長對比分析。結果髮現榦法脫硫異常數據時長遠低于濕法脫硫,無 GGH 脫硫 CEMS 故障率遠高于有GGH,高負荷時段、燃用高灰分煤種也使得 CEMS 的故障率提高。
대탈류 CMES 다발성고장적산생원인진행료분석연구,탐토료부하、매충파동대 CEMS 고장솔적영향,개전CEMS 고장시장대비분석。결과발현간법탈류이상수거시장원저우습법탈류,무 GGH 탈류 CEMS 고장솔원고우유GGH,고부하시단、연용고회분매충야사득 CEMS 적고장솔제고。
lt discusses the reasons of multiple faults of desulfurization CMES,analyzes the impact of load or coal fluctuations on the fault rate of CEMS and final y proposes comparison the CEMS fault time length. The results show that the time length of faults in dry process of desulfurizaation is much shorter than that in the wet process,the fault rate of desulfuration with GGH is much lower than that without GGH,measures including ap-plying high load and using high ash coal can also increase the fault rate of the CEMS.