解放军医药杂志
解放軍醫藥雜誌
해방군의약잡지
MEDICAL&PHARMACEUTICAL JOURNAL OF CHINESE PEOPLE'S LIBERATION ARMY
2014年
10期
90-93
,共4页
马慧萍%任俊%何蕾%李兰茹%董志臣%景临林%贾正平
馬慧萍%任俊%何蕾%李蘭茹%董誌臣%景臨林%賈正平
마혜평%임준%하뢰%리란여%동지신%경림림%가정평
雪莲黄酮胶囊%总黄酮%芦丁%色谱法,高压液相%质量控制
雪蓮黃酮膠囊%總黃酮%蘆丁%色譜法,高壓液相%質量控製
설련황동효낭%총황동%호정%색보법,고압액상%질량공제
Xuelianhuangtong capsules%Total flavonoids%Rutin%Chromatography,high pressure liquid%Quali-ty control
目的:建立抗高原缺氧药雪莲黄酮胶囊的质量控制标准。方法采用薄层色谱法定性鉴别雪莲的主要有效成分芦丁和绿原酸;采用紫外分光光度法测定制剂中总黄酮的含量,并采用高效液相色谱法测定其中芦丁的含量,色谱柱为Hypersil ODS2 C18柱(150 mm ×4.6 mm,5μm),流动相为甲醇-水(40:60),流速:1 ml/min;柱温为室温,检测波长为340 nm。结果薄层定性鉴别的斑点清晰,分离效果良好;总黄酮含量在9.84~59.04μg/ml浓度范围内具有良好的线性关系(r=0.9997),平均回收率为99.32%,RSD为1.47%(n=6);芦丁含量在4~120μg/ml浓度范围内具有良好的线性关系(r=0.9999),平均加样回收率为97.98%,RSD为1.35%(n=6)。结论本实验简便易行,结果准确可靠,重复性好,可作为该制剂的质量控制方法。
目的:建立抗高原缺氧藥雪蓮黃酮膠囊的質量控製標準。方法採用薄層色譜法定性鑒彆雪蓮的主要有效成分蘆丁和綠原痠;採用紫外分光光度法測定製劑中總黃酮的含量,併採用高效液相色譜法測定其中蘆丁的含量,色譜柱為Hypersil ODS2 C18柱(150 mm ×4.6 mm,5μm),流動相為甲醇-水(40:60),流速:1 ml/min;柱溫為室溫,檢測波長為340 nm。結果薄層定性鑒彆的斑點清晰,分離效果良好;總黃酮含量在9.84~59.04μg/ml濃度範圍內具有良好的線性關繫(r=0.9997),平均迴收率為99.32%,RSD為1.47%(n=6);蘆丁含量在4~120μg/ml濃度範圍內具有良好的線性關繫(r=0.9999),平均加樣迴收率為97.98%,RSD為1.35%(n=6)。結論本實驗簡便易行,結果準確可靠,重複性好,可作為該製劑的質量控製方法。
목적:건립항고원결양약설련황동효낭적질량공제표준。방법채용박층색보법정성감별설련적주요유효성분호정화록원산;채용자외분광광도법측정제제중총황동적함량,병채용고효액상색보법측정기중호정적함량,색보주위Hypersil ODS2 C18주(150 mm ×4.6 mm,5μm),류동상위갑순-수(40:60),류속:1 ml/min;주온위실온,검측파장위340 nm。결과박층정성감별적반점청석,분리효과량호;총황동함량재9.84~59.04μg/ml농도범위내구유량호적선성관계(r=0.9997),평균회수솔위99.32%,RSD위1.47%(n=6);호정함량재4~120μg/ml농도범위내구유량호적선성관계(r=0.9999),평균가양회수솔위97.98%,RSD위1.35%(n=6)。결론본실험간편역행,결과준학가고,중복성호,가작위해제제적질량공제방법。
Objective To establish the quality control standard for Xuelianhuangtong capsules against high-alti-tude hypoxia. Methods The Rutin and Chlorogenic Acid were identified by thin layer chromatography ( TLC);total fla-vonoids content were determined by ultraviolet spectrophotometry ( UV) , and Rutin content was determined by high per-formance liquid chromatography (HPLC). The Hypersil ODS2 C18(150 mm × 4. 6 mm, 5 μm) column was used, and the mobile phase consisted of methanol-water(40∶ 60), and the flow rate was 1 ml/min; the column temperature was room temperature, and the detection wavelength was at 340 nm. Results The spots in the TLC were clear with good dis-association effect;the good linear relationship was achieved within the range of total flavonoids content of 9. 84μg/ml-59. 04μg/ml (r=0. 9997), and its average recovery ratio was 99. 32% with 1. 47% of RSD (n=6);the good linear rela-tionship was achieved within the range of Rutin content of 4-120 μg/ml (r=0. 9999), and its average recovery of appli-cation of sample was 97. 98% with 1. 35% of RSD (n=6). Conclusion The method is simple, practical and accurate with good repeatability, so it can be used for the quality control of Xuelianhuangtong capsules.