西南国防医药
西南國防醫藥
서남국방의약
MEDICAL JOURNAL OF NATIONAL DEFENDING FORCES IN SOUTHWEST CHINA
2014年
10期
1057-1059
,共3页
张立广%岳文慧%张圣林%王荣吉%高东奇%张力
張立廣%嶽文慧%張聖林%王榮吉%高東奇%張力
장립엄%악문혜%장골림%왕영길%고동기%장력
肺癌%同机融合显像%化疗%摄取比
肺癌%同機融閤顯像%化療%攝取比
폐암%동궤융합현상%화료%섭취비
lung cancer%image fusion technology%chemotherapy%uptake ratio
目的:探讨99m Tc-MIBI SPECT/ CT 同机融合亲肿瘤显像预测肺癌化疗疗效的价值。方法43例化疗的肺癌患者分为有效组和无效组,在化疗前行99m Tc-MIBI SPECT/ CT 同机融合亲肿瘤显像,并对所摄取比值行半定量分析,比较两组早期相肿瘤/正常肺组织摄取比值(EUR)和延迟相肿瘤/正常肺组织摄取比值(DUR)、滞留指数(RI)之间的差别。结果化疗有效组的 EUR、DUR、RI 平均值均显著高于无效组(P <0.05);小细胞肺癌组的 EUR、DUR、RI 平均值均显著高于非小细胞肺癌组(P <0.05);肺腺癌组的 EUR、DUR、RI 平均值与肺鳞癌组无显著差异(P >0.05)。结论99m Tc-MIBI SPECT/ CT 同机融合亲肿瘤显像在预测肺癌化疗疗效方面具有重要的临床价值。
目的:探討99m Tc-MIBI SPECT/ CT 同機融閤親腫瘤顯像預測肺癌化療療效的價值。方法43例化療的肺癌患者分為有效組和無效組,在化療前行99m Tc-MIBI SPECT/ CT 同機融閤親腫瘤顯像,併對所攝取比值行半定量分析,比較兩組早期相腫瘤/正常肺組織攝取比值(EUR)和延遲相腫瘤/正常肺組織攝取比值(DUR)、滯留指數(RI)之間的差彆。結果化療有效組的 EUR、DUR、RI 平均值均顯著高于無效組(P <0.05);小細胞肺癌組的 EUR、DUR、RI 平均值均顯著高于非小細胞肺癌組(P <0.05);肺腺癌組的 EUR、DUR、RI 平均值與肺鱗癌組無顯著差異(P >0.05)。結論99m Tc-MIBI SPECT/ CT 同機融閤親腫瘤顯像在預測肺癌化療療效方麵具有重要的臨床價值。
목적:탐토99m Tc-MIBI SPECT/ CT 동궤융합친종류현상예측폐암화료료효적개치。방법43례화료적폐암환자분위유효조화무효조,재화료전행99m Tc-MIBI SPECT/ CT 동궤융합친종류현상,병대소섭취비치행반정량분석,비교량조조기상종류/정상폐조직섭취비치(EUR)화연지상종류/정상폐조직섭취비치(DUR)、체류지수(RI)지간적차별。결과화료유효조적 EUR、DUR、RI 평균치균현저고우무효조(P <0.05);소세포폐암조적 EUR、DUR、RI 평균치균현저고우비소세포폐암조(P <0.05);폐선암조적 EUR、DUR、RI 평균치여폐린암조무현저차이(P >0.05)。결론99m Tc-MIBI SPECT/ CT 동궤융합친종류현상재예측폐암화료료효방면구유중요적림상개치。
Objective To explore the value of 99m Tc-MIBI SPECT/ CT pro-tumor fusion image technology in predicting the effects of chemotherapy on lung cancer. Methods Total 43 patients receiving chemotherapy for lung cancer were collected and divided into effective group and ineffective group according to their chemotherapeutic result. Before the chemotherapy,all patients received 99m Tc-MIBISPECT/ CT pro-tumor fusion image examination,the semi-quantitative analysis was made to determine the uptake ratio,and the differences of the early-phase tumor/ normal lung tissue uptake ratio(EUR)and delayed-phase tumor/ normal lung tissue uptake ratio (DUR)as well as the retention index(RI)between the two groups were compared. Results The average values of EUR,DUR and RI of the patients in the effective group were significantly higher than those in the ineffective group(P < 0. 05),the ones in the small cell lung cancer(SCLC)group were significantly higher than those in the non-SCLC group(P < 0. 05),the ones in the lung adenocarcinoma group were no significantly different from those in the squamous cell lung cancer group(P > 0. 05). Conclusion 99m Tc-MIBI SPECT/ CT pro-tumor fusion image technology has important clinical values in predicting the effects of chemotherapy on lung cancer.