实用骨科杂志
實用骨科雜誌
실용골과잡지
JOURNAL OF PRACTICAL ORTHOPEDICS
2014年
10期
910-913
,共4页
吴泽海%王永清%董黎敏%周星衡%叶金铎%李毅%毕红宾
吳澤海%王永清%董黎敏%週星衡%葉金鐸%李毅%畢紅賓
오택해%왕영청%동려민%주성형%협금탁%리의%필홍빈
同种异体骨接骨板%可吸收螺钉%有限元分析%股骨
同種異體骨接骨闆%可吸收螺釘%有限元分析%股骨
동충이체골접골판%가흡수라정%유한원분석%고골
bone allograft bone plate%absorbable screws%the finite element analysis%the femoral
目的:对比分析异体骨接骨板分别联合可吸收螺钉(聚-DL-乳酸)和钛合金螺钉( Ti-6Al-4V)治疗股骨干骨折的应力分布情况,验证可吸收螺钉的强度,为临床提供力学依据。方法利用螺旋CT扫描股骨,将扫描数据以DICOM格式导入mimics软件中,建立股骨三维模型。在proe5.0中建立接骨板模型和螺钉模型(简化为圆柱),装配完成后,导入ansys12.0划分网格、材料赋值,并施加700 N轴向载荷、15 N·m弯曲载荷、15 N·m扭转载荷。结果在三种载荷下6根可吸收螺钉最大主应力的最大值为5.75 Mpa、6根钛合金螺钉最大主应力的最大值为24.9 Mpa;两种不同螺钉固定下,股骨和接骨板的应力分布基本相同。结论可吸收螺钉适应于同种异体骨接骨板的固定,与钛合金螺钉相比,具有减少骨头螺钉孔处的应力遮挡的优点。
目的:對比分析異體骨接骨闆分彆聯閤可吸收螺釘(聚-DL-乳痠)和鈦閤金螺釘( Ti-6Al-4V)治療股骨榦骨摺的應力分佈情況,驗證可吸收螺釘的彊度,為臨床提供力學依據。方法利用螺鏇CT掃描股骨,將掃描數據以DICOM格式導入mimics軟件中,建立股骨三維模型。在proe5.0中建立接骨闆模型和螺釘模型(簡化為圓柱),裝配完成後,導入ansys12.0劃分網格、材料賦值,併施加700 N軸嚮載荷、15 N·m彎麯載荷、15 N·m扭轉載荷。結果在三種載荷下6根可吸收螺釘最大主應力的最大值為5.75 Mpa、6根鈦閤金螺釘最大主應力的最大值為24.9 Mpa;兩種不同螺釘固定下,股骨和接骨闆的應力分佈基本相同。結論可吸收螺釘適應于同種異體骨接骨闆的固定,與鈦閤金螺釘相比,具有減少骨頭螺釘孔處的應力遮擋的優點。
목적:대비분석이체골접골판분별연합가흡수라정(취-DL-유산)화태합금라정( Ti-6Al-4V)치료고골간골절적응력분포정황,험증가흡수라정적강도,위림상제공역학의거。방법이용라선CT소묘고골,장소묘수거이DICOM격식도입mimics연건중,건립고골삼유모형。재proe5.0중건립접골판모형화라정모형(간화위원주),장배완성후,도입ansys12.0화분망격、재료부치,병시가700 N축향재하、15 N·m만곡재하、15 N·m뉴전재하。결과재삼충재하하6근가흡수라정최대주응력적최대치위5.75 Mpa、6근태합금라정최대주응력적최대치위24.9 Mpa;량충불동라정고정하,고골화접골판적응력분포기본상동。결론가흡수라정괄응우동충이체골접골판적고정,여태합금라정상비,구유감소골두라정공처적응력차당적우점。
Objective To comparative analysis of two different screws allogeneic bone plate in the treatment of femoral fracture stress distribution,and to provide the mechanical basis for the clinical. Methods CT images of femur were obtained from spiral ct,which were subsequently imported into mimics software according to DICOM standard,and then built a three-di-mensional model of the femur. Built bone plates model and screws model(simplified cylinder)in proe 5. 0 and then importing into ansys12. 0 meshed and assigned with material properties after assembly was completed. And applying 700N axial load,15 N·M bending load,15 N·M torsional load. The maximum value of 6 absorbable screw's maximum principal stress is 5. 75 Mpa,of 6 titanium screws is 24. 9 Mpa under the three load. Two different screws,the stress distribution of the femur and the bone plate is substantially the same. Conclusion Absorbable screw adapted to allogeneic bone plates fixation,compared with titanium screws,has the advantage of reducing the bone screw holes at the stress shielding.