中华现代护理杂志
中華現代護理雜誌
중화현대호리잡지
CHINESE JOURNAL OF MODERN NURSING
2014年
28期
3641-3643
,共3页
王桂荣%吴蔚%杨凤翔%赵晓庆
王桂榮%吳蔚%楊鳳翔%趙曉慶
왕계영%오위%양봉상%조효경
护理%膀胱尿压测定评定系统%糖尿病神经源性膀胱
護理%膀胱尿壓測定評定繫統%糖尿病神經源性膀胱
호리%방광뇨압측정평정계통%당뇨병신경원성방광
Nursing care%Urinary bladder pressure measurement evaluation system%Diabetic neurogenic bladder
目的:观察膀胱尿压测定评定系统在糖尿病神经源性膀胱( DNB )护理中的应用效果。方法选择住院治疗的糖尿病神经源性膀胱患者50例,应用膀胱尿压测定评定系统了解膀胱压力容量变化、膀胱安全容量和最大容量、逼尿肌起始活动状态,括约肌状态、逼尿肌/括约肌协同能力,据此制订护理方案并实施,比较干预前后膀胱残余尿量及排尿功能变化。结果本组患者中尿失禁9例,尿潴留40例;膀胱训练后膀胱残余尿量>200 ml患者从20例降至5例,中重度排尿功能障碍患者从22例降至7例,训练前后比较差异有统计学意义(U值分别为4.73,5.51;P<0.01)。低顺应性小容量膀胱1例,转外科手术治疗。结论膀胱尿压测定评定系统用于糖尿病神经源性膀胱护理安全可行,可减少膀胱残余尿量,改善排尿功能。
目的:觀察膀胱尿壓測定評定繫統在糖尿病神經源性膀胱( DNB )護理中的應用效果。方法選擇住院治療的糖尿病神經源性膀胱患者50例,應用膀胱尿壓測定評定繫統瞭解膀胱壓力容量變化、膀胱安全容量和最大容量、逼尿肌起始活動狀態,括約肌狀態、逼尿肌/括約肌協同能力,據此製訂護理方案併實施,比較榦預前後膀胱殘餘尿量及排尿功能變化。結果本組患者中尿失禁9例,尿潴留40例;膀胱訓練後膀胱殘餘尿量>200 ml患者從20例降至5例,中重度排尿功能障礙患者從22例降至7例,訓練前後比較差異有統計學意義(U值分彆為4.73,5.51;P<0.01)。低順應性小容量膀胱1例,轉外科手術治療。結論膀胱尿壓測定評定繫統用于糖尿病神經源性膀胱護理安全可行,可減少膀胱殘餘尿量,改善排尿功能。
목적:관찰방광뇨압측정평정계통재당뇨병신경원성방광( DNB )호리중적응용효과。방법선택주원치료적당뇨병신경원성방광환자50례,응용방광뇨압측정평정계통료해방광압력용량변화、방광안전용량화최대용량、핍뇨기기시활동상태,괄약기상태、핍뇨기/괄약기협동능력,거차제정호리방안병실시,비교간예전후방광잔여뇨량급배뇨공능변화。결과본조환자중뇨실금9례,뇨저류40례;방광훈련후방광잔여뇨량>200 ml환자종20례강지5례,중중도배뇨공능장애환자종22례강지7례,훈련전후비교차이유통계학의의(U치분별위4.73,5.51;P<0.01)。저순응성소용량방광1례,전외과수술치료。결론방광뇨압측정평정계통용우당뇨병신경원성방광호리안전가행,가감소방광잔여뇨량,개선배뇨공능。
Objective To observe the application effect of the urinary bladder pressure measurement evaluation system in the nursing of diabetic neurogenic bladder .Methods Fifty patients with diabetic neurogenic bladder two days after hospitalization from March 2011 to August 2013 were chosen .The change of bladder pressure and volume , the bladder safe capacity and maximum capacity , the starting activity state of detrusor, the state of sphincter, and the coordination ability of detrusor/sphincter were measured by the urinary bladder pressure meter .The nursing plan were made and carried out according to the results of measures .The residual urine volumes of bladder and the urination function changes were compared before and after the intervention .Results The cases of urinary incontinence ( high compliance small capacity bladder ) and the urinary retention ( high compliance large capacity bladder ) were respectively 9 and 40 cases.The cases of residual urine volumes of bladder more than 200 ml were decreased from 20 cases to 5 cases after the training of bladder , and the cases of patients with moderate and severe disorder of urination function were decreased from 22 cases to 7 cases after the training, and the differences were found before and after the training (U=4.73, 5.51, respectively;P<0.01).The case of low compliance small capacity bladder was one case , and was needed to the treatment of surgery .Conclusions Application of the urinary bladder pressure measurement evaluation system in the nursing of diabetic neurogenic bladder is safe and feasible , and can reduce the residual urine volumes of bladder , and improve the urination function .