济宁医学院学报
濟寧醫學院學報
제저의학원학보
JOURNAL OF JINING MEDICAL COLLEGE
2014年
5期
320-322
,共3页
王皆欢%陈东风%王少春%孙占国%王林省%张谷青
王皆歡%陳東風%王少春%孫佔國%王林省%張穀青
왕개환%진동풍%왕소춘%손점국%왕림성%장곡청
双源CT%胸痛三联血管成像%辐射剂量
雙源CT%胸痛三聯血管成像%輻射劑量
쌍원CT%흉통삼련혈관성상%복사제량
Dual-source CT%Triple-rule-out CT angiography%Radiation dose
目的:对比双源CT胸痛三联检查在两种不同电压下显示急性胸痛患者肺动脉、主动脉及冠状动脉的图像质量以及患者所受的辐射剂量,以评估低电压扫描在急性胸痛患者推广应用的可行性。方法利用双源C T胸痛三联扫描模式,结合回顾性心电门控技术对361例胸痛三联检查患者进行统计分析,比较主动脉、肺动脉及冠状动脉的图像质量及辐射的有效剂量。结果120kV组与100kV组在图像质量的主观评分对比中差异无统计学意义(P>0.05),在患者辐射剂量的对比中,120kV组的辐射剂量大于100kV组,差异有统计学意义(P<0.05)。结论双源CT胸痛三联检查两种不同管电压扫描对急性胸痛患者的肺动脉、主动脉及冠状动脉的成像质量无影响,并且应用100kV 管电压扫描可以降低患者所受的辐射剂量,可以作为急性胸痛患者的首选。
目的:對比雙源CT胸痛三聯檢查在兩種不同電壓下顯示急性胸痛患者肺動脈、主動脈及冠狀動脈的圖像質量以及患者所受的輻射劑量,以評估低電壓掃描在急性胸痛患者推廣應用的可行性。方法利用雙源C T胸痛三聯掃描模式,結閤迴顧性心電門控技術對361例胸痛三聯檢查患者進行統計分析,比較主動脈、肺動脈及冠狀動脈的圖像質量及輻射的有效劑量。結果120kV組與100kV組在圖像質量的主觀評分對比中差異無統計學意義(P>0.05),在患者輻射劑量的對比中,120kV組的輻射劑量大于100kV組,差異有統計學意義(P<0.05)。結論雙源CT胸痛三聯檢查兩種不同管電壓掃描對急性胸痛患者的肺動脈、主動脈及冠狀動脈的成像質量無影響,併且應用100kV 管電壓掃描可以降低患者所受的輻射劑量,可以作為急性胸痛患者的首選。
목적:대비쌍원CT흉통삼련검사재량충불동전압하현시급성흉통환자폐동맥、주동맥급관상동맥적도상질량이급환자소수적복사제량,이평고저전압소묘재급성흉통환자추엄응용적가행성。방법이용쌍원C T흉통삼련소묘모식,결합회고성심전문공기술대361례흉통삼련검사환자진행통계분석,비교주동맥、폐동맥급관상동맥적도상질량급복사적유효제량。결과120kV조여100kV조재도상질량적주관평분대비중차이무통계학의의(P>0.05),재환자복사제량적대비중,120kV조적복사제량대우100kV조,차이유통계학의의(P<0.05)。결론쌍원CT흉통삼련검사량충불동관전압소묘대급성흉통환자적폐동맥、주동맥급관상동맥적성상질량무영향,병차응용100kV 관전압소묘가이강저환자소수적복사제량,가이작위급성흉통환자적수선。
Objective To compare the value of triple-rule-out (TRO) dual-source computed tomography angiog-raphy in acute chest pain patients with diseases of pulmonary artery ,aortic and coronary artery and radiation dose in two different voltage as well as the feasibility of generalizing and applying in patients with acute chest pain . Methods 361 patients with chest pain were analyzed statistically underwent triple-rule-out (TRO) dual-source CT combined with retrospective ECG-gated technique ,and then compare with image quality of aorta ,pulmonary artery and coronary artery and effective radiation dose .Results Subjective score of image quality of the voltage 120kV and 100kV group had no statistical significance(P>0.05) .The difference was statistically significant(P<0.05)in comparison of radiation dose .The effective radiation dose of the voltage 100kV group was lower than that of the voltage 120kV group .Conclusion The quality of pictures of pulmonary artery ,coronary artery and aorta are not affected in different tube tension examination of triple-rule-out (TRO) with dual-source CT ,and the radiation dose is reduced with tube tension 100kV which is regarded as the first choice for the patients with acute chest pain .