水利与建筑工程学报
水利與建築工程學報
수리여건축공정학보
TECHNIQUE OF SEEPAGE CONTROL
2014年
5期
113-118
,共6页
粘弹性边界%地下厂房%位移%应力%内力
粘彈性邊界%地下廠房%位移%應力%內力
점탄성변계%지하엄방%위이%응력%내력
viscous-spring boundary%underground powerhouse%displacement%stress%inner force
为充分利用围岩的支撑作用,减小结构变形和振动,地下厂房结构通常会采用锚杆将上下游侧立柱与围岩紧密连接,但此种处理措施对地下厂房地震反应的影响尚不明确。为了解立柱与围岩连接方式对地下厂房地震反应的影响,通过使用显式动力有限元分析软件LS-DYNA ,基于粘弹性边界理论和等效地震荷载输入方法,计算分析了水电站地下厂房结构的地震反应。计算结果表明,与采用锚杆将上下游立柱与围岩紧密连接时相比,立柱与围岩分离时,立柱及与立柱相连的楼板和风罩等上部结构在水平地震下的位移反应有所减小,动拉应力值明显下降,特别是上下游侧立柱的内力会大幅降低。由此可见,将上下游侧立柱与岩体分离对减小地下厂房结构的地震反应更为有利。
為充分利用圍巖的支撐作用,減小結構變形和振動,地下廠房結構通常會採用錨桿將上下遊側立柱與圍巖緊密連接,但此種處理措施對地下廠房地震反應的影響尚不明確。為瞭解立柱與圍巖連接方式對地下廠房地震反應的影響,通過使用顯式動力有限元分析軟件LS-DYNA ,基于粘彈性邊界理論和等效地震荷載輸入方法,計算分析瞭水電站地下廠房結構的地震反應。計算結果錶明,與採用錨桿將上下遊立柱與圍巖緊密連接時相比,立柱與圍巖分離時,立柱及與立柱相連的樓闆和風罩等上部結構在水平地震下的位移反應有所減小,動拉應力值明顯下降,特彆是上下遊側立柱的內力會大幅降低。由此可見,將上下遊側立柱與巖體分離對減小地下廠房結構的地震反應更為有利。
위충분이용위암적지탱작용,감소결구변형화진동,지하엄방결구통상회채용묘간장상하유측립주여위암긴밀련접,단차충처리조시대지하엄방지진반응적영향상불명학。위료해립주여위암련접방식대지하엄방지진반응적영향,통과사용현식동력유한원분석연건LS-DYNA ,기우점탄성변계이론화등효지진하재수입방법,계산분석료수전참지하엄방결구적지진반응。계산결과표명,여채용묘간장상하유립주여위암긴밀련접시상비,립주여위암분리시,립주급여립주상련적루판화풍조등상부결구재수평지진하적위이반응유소감소,동랍응력치명현하강,특별시상하유측립주적내력회대폭강저。유차가견,장상하유측립주여암체분리대감소지하엄방결구적지진반응경위유리。
To make full use of the surrounding rocks and reduce deformation and vibration of the structure ,anchors are commonly used for connecting upstream and downstream side columns with surrounding rocks .But the influences of this measure on the seismic response of the underground powerhouse remains unclear .To research the effects of connection type between surrounding rock and columns along the upstream and the downstream sides on the seismic response of un-derground powerhouse ,the seismic response of underground powerhouse is analyzed by the explicit dynamic finite element analysis software LS -DYNA based on viscous-spring boundary theory and equivalent seismic load input method .The re-sults indicate that ,comparing with anchoring the upstream and downstream side columns on the surrounding rocks ,keep-ing separation between columns and rock can reduce the displacement response and the dynamic tensile stress of the upper structures such as floor slabs and wind cover .Especially the internal force of the upstream and downstream side columns will be greatly reduced when separating them from the surrounding rocks .So ,it can be concluded that ,separating the upstream and downstream side columns from the surrounding rocks is beneficial in reducing the seismic response of under-ground powerhouse structure .